Alpha Wire 78006 SL001, ECOGEN ECOCABLE Mini 28 AWG 6C Unshielded 300 V MPPE

SKU:78006 SL001
● In stock
ft
Minimum order: 100 ft
Description
Part Number: 78006 SL001
Alpha Wire 78006 SL001 ECOGEN ECOCABLE Mini is a compact, unshielded multi-Conductor cable built with 28 AWG Tinned Copper Stranded Conductors and MPPE-modified polyphenylene Insulation and Jacket. It features a 6 X 1 Cond construction with 9.6 Twists/foot (min) cabling and a nonwoven polyester tape core wrap for stable assembly. Rated 300 V and 80C, it is marked for VW-1 and FT1 performance and includes sequential footage printing for easier installation and tracking. The Jacket is available in Slate, White and includes a nylon ripcord for efficient stripping.
Conductor
- Number Of Conductors: 3 Conductors
- Construction: 6 X 1 Cond
- Conductor Size: 28 AWG (American Wire Guage)
- Conductor Stranding: 28 (19/40) AWG Tinned Copper
- Conductor Material: Tinned Copper
- Conductor Type: Stranded Conductor
- Conductor Diameter (In): 0.016
Insulation
- Insulation Material: MPPE-Modified Polyphenylene
- Insulation: 0.007" Wall, Nom. Modified Polyphenylene Ether-PE
- Insulated Conductor Diameter (In): 0.030
- Color Code: Alpha Wire Color Code E
- Conductor Colors: 1 Black; 2 Brown; 3 Red; 4 Orange; 5 Yellow; 6 Green
Cabling / Core
- Cable Assembly: 6 Components Cabled
- Twists: 9.6 Twists/foot (min)
- Orientation: Components to be arranged from Inside Layer to Outside Layer
- Core Wrap: Nonwoven Polyester Tape, 25% Overlap, Min.
Jacket
- Jacket Material: MPPE-Modified Polyphenylene
- Jacket: 0.015" Wall, Nom.,Modified Polyphenylene Ether-PE
- Overall Diameter (In): 0.124 (0.133 Max.)
- Jacket Color(s): Slate, White
- Ripcord: 1 End 810 Denier Nylon
Ratings & Compliance
- Voltage Rating: 300 V
- Temperature Rating: 80C
- Fire Rating: General Purpose
- Screen/Shield: No
- NEC Rating: Not Listed by UL Under NEC
Cable Print (As Marked)
- ALPHA WIRE-* P/N 78006 6C 28 AWG
ECOCABLE(R) MINI RU AWM 21460 80C 300V VW-1
C(RU) AWM I A/B FT1 80C 300V
CE ROHS (SEQ FOOTAGE)
* = Factory Code
Specifications
| Attribute | Value |
|---|---|
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.