UL 1008 Code Summary:
UL 1008 pertains to single conductor wiring with extruded PVC insulation, used for internal appliance wiring. It is rated for 80°C and 300V AC, with horizontal flame resistance. The wiring can withstand oil exposure at either 60°C or 80°C. The conductor ranges from 28 AWG to 12 AWG, and the insulation includes optional nylon or lacquered braid covering.
Specifications:
- Rating: 80°C, 300V AC
- Conductor: 28 AWG - 12 AWG, solid/stranded
- Insulation: PVC, 15 mils avg, 13 mils min
- Covering: Nylon (2 mils min) or lacquered braid
- Usage: Internal appliance wiring, oil-resistant
- Standard: UL 758
See more information about UL Style 1008 here.
Looking for UL 1008 Cables?
Our team will be more than happy to guide you to the right choice for your application.
*Disclaimer: This article is provided for informational purposes only and is not installation advice. Installing wire & cable can be dangerous and pose a risk of possible electric shock or other hazards. Consult a licensed professional for installation advice. Images are for illustration purposes and may not reflect actual installed products