Belden 1034A 010, Power Limited Tray Cable 1 Triad 16 AWG 300V PVC, Black Jacket

SKU:Belden 1034A
● In stock
Description
Belden 1034A 010 is a power limited tray cable for instrumentation and industrial control wiring in raceways, cable trays, and ducts. It is built with 1 triad of 16 AWG (7x24) BC - Bare Copper stranded conductors, PVC - Polyvinyl Chloride insulation, and a black PVC - Polyvinyl Chloride outer jacket. This unshielded cable is rated 300 V and is listed/marked PLTC ITC CMG AWM 2464 SUN RES for indoor and outdoor use with sunlight resistance.
Belden 1034A 010 Key Features
- Power limited tray cable construction for instrumentation and industrial control wiring in raceways, cable trays, and ducts.
- 1 triad (3 conductors) of 16 AWG (7x24) BC - Bare Copper stranded conductors.
- PVC - Polyvinyl Chloride insulation with color code: Black, Red, White.
- Unshielded design (Outer Shield: No Shield; Shield Type: Unshielded).
- Black PVC - Polyvinyl Chloride outer jacket with Ripcord: Yes.
- UL voltage rating: 300 V.
- Listings/markings: PLTC ITC CMG AWM 2464 SUN RES.
- Environmental suitability: Indoor, Outdoor, Sunlight Resistance.
Belden 1034A 010 Applications
- Use in industrial control wiring where a power limited tray cable is specified.
- Install in raceways, cable trays, and ducts for organized routing in industrial environments.
- Support digital control circuits, including low voltage digital control (24v, …).
- Run instrumentation signals for instruments (4-20ma, 0-10v, ...).
- Integrate into distributed control system (DCS) and programmable logic controller (PLC) wiring.
- Connect thermocouples where this cable type is selected.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor count | 1 Triad |
| Conductor size | 16 AWG |
| Stranding | 7x24 |
| Conductor Material | BC - Bare Copper |
| Conductor Type | Stranded Conductor |
| Insulation Material | PVC - Polyvinyl Chloride |
| Insulation nom. thickness | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.091 in (2.3 mm) |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Jacket nom. thickness | 0.037 in (0.94 mm) |
| Nom. diameter | 0.270 in |
| Overall cable diameter (nominal) | 0.270 in |
| Bulk cable weight | 48 lbs/1000ft |
| Nom. conductor DCR | 4.2 Ohm/1000ft |
| Max. current | 19 Amps per Conductor at 25ºC |
| UL temperature | UL: 105°C, AWM 2464: 80°C |
| Operating temperature | -20°C to +105°C |
| Bend radius (stationary min.) | 2.7 in (69 mm) |
| Bend radius (installation min.) | 2.7 in |
| Max Pull Tension | 107 lbs (48.5 kg) |
| NEC / UL compliance | Article 725, Article 727, Article 800 |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL1685 FT4 Loading, FT4, IEEE 1202 FT4 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable, PLTC |
| Other Part Numbers | 1034A 0101000, 1034A 010, 1034A 010100, 1034A 010250, 1034A 010500 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.