Belden 1039A 010, Power Limited Tray Cable 4 Pairs 16 AWG 600V PVC, Black Jacket

SKU:Belden 1039A
● In stock
Description
Belden 1039A 010 is a power limited tray cable designed for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It is built with 4 twisted pairs of 16 AWG (7x24) BC - Bare Copper conductors with PVC/Nylon - Polyvinyl Chloride + Nylon insulation and ICEA Chart E1 color code. For noise rejection, it uses Individual & Overall Beldfoil® Shield under a black PVC - Polyvinyl Chloride outer jacket. UL Voltage Rating is 600 V (TC-ER), 150 V (NPLF), with environmental suitability listed as Indoor/Outdoor, Sunlight Resistance, and Burial.
Belden 1039A 010 Key Features
- Power limited tray cable for industrial control and instrumentation wiring in raceways, cable trays, and ducts.
- 4 twisted pairs of 16 AWG (7x24) BC - Bare Copper conductors with ICEA Chart E1 color code.
- Individual & Overall Beldfoil® Shield for noise rejection in demanding environments.
- Black PVC - Polyvinyl Chloride outer jacket with Ripcord: Yes.
- UL Voltage Rating: 600 V (TC-ER), 150 V (NPLF).
- Environmental suitability: Indoor/Outdoor, Sunlight Resistance, Burial.
Belden 1039A 010 Applications
- Use in industrial control systems where power limited tray cable is specified for control and instrumentation wiring.
- Route through raceways, cable trays, and ducts in industrial installations.
- Support digital control and low voltage digital control (24v, …) signal distribution in control networks.
- Apply to instruments (4-20ma, 0-10v, ...) where consistent signal handling is required.
- Commonly use for encoders and control circuits in automation equipment.
- Fit distributed control system (DCS) and programmable logic controller (PLC) wiring where organized multi-pair runs are needed.
- Connect solenoids, valves, actuators, and positioners in industrial control and instrumentation setups.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 4 |
| Element type | pair(s) |
| Conductor size | 16 AWG |
| Stranding | 7x24 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Insulation nominal thickness | 0.022 in (0.56 mm) |
| Insulation nominal diameter | 0.101 in (2.57 mm) |
| Color Code | ICEA Chart E1 |
| Inner shield (each pair) | Tape; Bi-Laminate (Alum+Poly); 100% coverage; drainwire 18 AWG (7x26) TC |
| Outer shield | Tape; Bi-Laminate (Alum+Poly); 100% coverage; drainwire 16 AWG (7x24) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Jacket nominal thickness | 0.064 in (1.6 mm) |
| Nom. conductor DCR | 4.2 Ohm/1000ft |
| Nom. inner shield DCR | 5.49 Ohm/1000ft (18.0 Ohm/km) |
| Nom. outer shield DCR | 3.14 Ohm/1000ft (10.3 Ohm/km) |
| Max. current | 13 Amps per Conductor @ 30°C |
| Overall cable diameter (nominal) | 0.574 in (14.6 mm) |
| Bend radius (stationary min.) | 6.9 in (180 mm) |
| Bend radius (installation min.) | 6.9 in (180 mm) |
| Max Pull Tension | 344 lbs (156 kg) |
| Bulk cable weight | 188 lbs/1000ft |
| UL temperature | 90°C Dry, 90°C Wet |
| Operating temperature | -30°C to 90°C Dry/Wet |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC-ER |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | 07-KA080011-MSHA |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.