Belden 1040A 010, Power Limited Tray Cable 6PR 16 AWG 600V PVC, Black Jacket

SKU:Belden 1040A
● In stock
Description
Belden 1040A 010 is a UL instrumentation, power limited tray cable designed for industrial control and instrumentation circuits in raceways, cable trays, and ducts. It features 6 pair 16 AWG (7x24) BC - Bare Copper stranded conductors with PVC/Nylon - Polyvinyl Chloride + Nylon insulation and ICEA Chart E1 color coding for consistent identification. For noise-sensitive signals, it includes both individual and overall shields, including an overall Beldfoil® Shield with 100% coverage. Rated 600 V (TC-ER) and 150 V (NPLF), it supports 90°C dry and 90°C wet service and uses a black PVC - Polyvinyl Chloride outer jacket for indoor/outdoor, sunlight resistance, and burial.
Belden 1040A 010 Key Features
- 6 pair construction with 16 AWG (7x24) BC - Bare Copper stranded conductors.
- PVC/Nylon - Polyvinyl Chloride + Nylon insulation with ICEA Chart E1 color code for consistent identification.
- Both individual and overall shields, including an overall Beldfoil® Shield with 100% coverage.
- UL voltage rating: 600 V (TC-ER), 150 V (NPLF).
- UL temperature: 90°C dry, 90°C wet.
- Black PVC - Polyvinyl Chloride outer jacket with environmental suitability for indoor/outdoor, sunlight resistance, and burial.
Belden 1040A 010 Applications
- Use it in industrial control systems where instrumentation and control circuits are routed through raceways, cable trays, and ducts.
- Support digital control and low voltage digital control (24v, …) signal connections in control circuits.
- Connect instruments (4-20ma, 0-10v, ...) where consistent identification is needed.
- Use it for encoders in control and instrumentation setups.
- Fit distributed control system (DCS) installations that require organized multi-pair signal wiring.
- Use it with programmable logic controller (PLC) wiring in industrial automation panels and systems.
- Support connections to solenoids, valves, actuators, and positioners in industrial control circuits.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 6 |
| Element type | pair(s) |
| Conductor Type | Stranded Conductor |
| Insulation thickness (nom.) | 0.022 in (0.56 mm) |
| Insulation diameter (nom.) | 0.101 in (2.57 mm) |
| Shield configuration | Both individual and overall shields |
| Inner shield (each pair) | Tape, Bi-Laminate (Alum+Poly), 100% coverage, drainwire 18 AWG (7x26) TC |
| Outer shield | Tape, Bi-Laminate (Alum+Poly), 100% coverage, drainwire 16 AWG (7x24) TC |
| Jacket thickness (nom.) | 0.064 in (1.6 mm) |
| Overall cable diameter (nom.) | 0.670 in (17.0 mm) |
| Ripcord | Yes |
| Armor | No |
| Bulk cable weight | 264 lbs/1000ft |
| Conductor DCR (nom.) | 4.2 Ohm/1000ft |
| Inner shield DCR (nom.) | 5.49 Ohm/1000ft (18.0 Ohm/km) |
| Outer shield DCR (nom) | 3.01 Ohm/1000ft (9.88 Ohm/km) |
| Inductance (nom.) | 0.182 µH/ft (0.597 µH/m) |
| Max. current | 9 Amps per Conductor @ 30°C |
| Operating temperature | -30°C to 90°C Dry/Wet |
| Bend radius (stationary min.) | 8.0 in (200 mm) |
| Bend radius (installation min.) | 8.0 in (200 mm) |
| Max Pull Tension | 486 lbs (220 kg) |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4 |
| Thermocouple | No |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC-ER |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | 07-KA080011-MSHA |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.