Belden 1063A 010, Power Limited Tray Cable 2P 18 AWG 600V PVC, Black Jacket

SKU:Belden 1063A
● In stock
Description
Belden 1063A 010 is a power limited tray cable designed for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It features 2 pair 18 AWG (7x26) BC - Bare Copper conductors with PVC/Nylon - Polyvinyl Chloride + Nylon insulation and ICEA Chart E1 color coding for consistent identification. An overall Beldfoil® shield with 100% coverage helps reduce noise in digital control, PLC, DCS, and 4-20ma / 0-10v signal applications. The black PVC outer jacket is rated 600 V (TC-ER), 150 V (NPLF), and 90°C Dry, 90°C Wet, with Sunlight Resistance and Burial suitability.
Belden 1063A 010 Key Features
- Power limited tray cable construction for industrial control and instrumentation wiring in raceways, cable trays, and ducts.
- 2 pair 18 AWG (7x26) BC - Bare Copper stranded conductors for control and instrumentation circuits.
- PVC/Nylon - Polyvinyl Chloride + Nylon insulation with ICEA Chart E1 color coding for consistent conductor identification.
- Overall Beldfoil® shield with 100% coverage helps reduce noise in digital control, PLC, DCS, and 4-20ma / 0-10v signal applications.
- Black PVC - Polyvinyl Chloride outer jacket with UL voltage rating: 600 V (TC-ER), 150 V (NPLF), and UL temperature: 90°C Dry, 90°C Wet.
- Environmental suitability includes Indoor/Outdoor, Sunlight Resistance, and Burial.
Belden 1063A 010 Applications
- Supports industrial control and instrumentation wiring routed through raceways, cable trays, and ducts.
- Enables digital control signal wiring, including programmable logic controller (PLC) and distributed control system (DCS) connections.
- Commonly used with instruments carrying 4-20ma and 0-10v signals.
- Works well in low voltage digital control (24v, …) circuits.
- Used in control circuits for devices such as encoders, solenoids, valves, actuators, and positioners.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Elements | 2 pair |
| Conductor size | 18 AWG |
| Stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Conductor Type | Stranded Conductor |
| Insulation thickness (nom.) | 0.022 in (0.56 mm) |
| Insulation diameter (nom.) | 0.088 in (2.2 mm) |
| Color Code | ICEA Chart E1 |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 18 AWG (7x26) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Jacket thickness (nom.) | 0.047 in (1.2 mm) |
| Overall cable diameter (nom.) | 0.405 in (10.3 mm) |
| Ripcord | Yes |
| Armor | No |
| Nom. conductor DCR | 6.93 Ohm/1000ft |
| Max. current | 11 Amps per Conductor @ 30°C |
| Nom. outer shield DCR | 4.75 Ohm/1000ft (15.6 Ohm/km) |
| Operating temperature | -30°C to 90°C Dry/Wet |
| Bend radius (stationary min.) | 4.9 in (120 mm) |
| Bend radius (installation min.) | 4.9 in (120 mm) |
| Max Pull Tension | 112 lbs (50.8 kg) |
| Bulk cable weight | 67 lbs/1000ft |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC-ER |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.