Belden 1067A 010, Power Limited Tray Cable 16PR 18 AWG 600V PVC, Black Jacket

SKU:Belden 1067A
● In stock
Description
Belden 1067A 010 is a power limited tray cable designed for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It is built with 16 pair 18AWG (7x26) BC - Bare Copper conductors with PVC/Nylon - Polyvinyl Chloride + Nylon insulation and an overall Beldfoil® Shield with 100% coverage. The black PVC - Polyvinyl Chloride outer jacket includes a ripcord and supports indoor, outdoor, sunlight resistance, and burial environments. Electrical and compliance details include 600 V (TC-ER), 150 V (NPLF), UL 1685 UL loading, IEEE 1202 FT4, and NEC / UL compliance to Article 336, Article 760, NPLF, TC-ER.
Belden 1067A 010 Key Features
- Power limited tray cable construction for industrial control and instrumentation wiring in raceways, cable trays, and ducts.
- 16 pair 18AWG (7x26) stranded conductors using BC - Bare Copper.
- PVC/Nylon - Polyvinyl Chloride + Nylon insulation with E1 color code for consistent identification.
- Overall Beldfoil® Shield (tape) with 100% coverage and Bi-Laminate (Alum+Poly) shield material.
- Black PVC - Polyvinyl Chloride outer jacket with ripcord.
- UL voltage rating: 600 V (TC-ER), 150 V (NPLF).
- Environmental suitability: indoor, outdoor, sunlight resistance, burial.
- Flammability / reaction to fire: UL 1685 UL loading, IEEE 1202 FT4.
- NEC / UL compliance: Article 336, Article 760, NPLF, TC-ER.
- European directive compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE).
- APAC compliance: China RoHS II (GB/T 26572-2011).
Belden 1067A 010 Applications
- It is used in industrial control systems where reliable signal and control wiring is required.
- It is installed in raceways, cable trays, and ducts to support organized routing in industrial environments.
- Digital control wiring is supported where noise reduction is important.
- Instrument (4-20ma, 0-10v, ...) signal connections are supported.
- Low voltage digital control (24v, …) circuits are supported.
- Encoders are supported in control and instrumentation setups.
- Control circuits are supported for industrial automation and process control.
- Distributed control system (DCS) installations are supported.
- Programmable logic controller (PLC) wiring is supported.
- Solenoids are supported in control systems.
- Valves and related control wiring are supported.
- Actuators are supported in automated equipment.
- Positioners are supported in instrumentation and control loops.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of pairs | 16 |
| Conductor size | 18 |
| Stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Conductor Type | Stranded conductor |
| Insulation thickness (nom.) | 0.016 in (0.41 mm) |
| Insulation diameter (nom.) | 0.078 in (2.0 mm) |
| Color Code | Black, White and Numbered |
| Shield | Yes - this has a shield |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 18 AWG (7x26) TC |
| Armor | No |
| Jacket thickness (nom.) | 0.064 in (1.6 mm) |
| Nom. diameter | 0.793 in (20.1 mm) |
| Bulk cable weight | 341 lbs/1000ft |
| Nom. conductor DCR | 6.79 Ohm/1000ft |
| Nom. outer shield DCR | 0.8 Ohm/1000ft (2.6 Ohm/km) |
| Max. current | 6 Amps per Conductor at 25ºC |
| UL temperature | 90°C Dry, 90°C Wet |
| Operating | Wet/Dry: -30°C to 90°C |
| Bend radius (stationary min.) | 3.16 in (80.3 mm) |
| Bend radius (installation min.) | 3.95 in (100 mm) |
| Max Pull Tension | 739 lbs (335 kg) |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.