Belden 1070A 010, Power Limited Tray Cable 8C 16 AWG 600V PVC, Black Jacket

SKU:Belden 1070A
● In stock
Description
Belden 1070A 010 is a power limited tray cable designed for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It is built with 4 pair 16 AWG (7x24) bare copper conductors, PVC/Nylon insulation, and ICEA Chart E1 color coding for consistent identification. For noise rejection, it includes an overall Beldfoil® shield with 100% coverage and a 16 AWG (7x24) TC drainwire, finished with a black PVC outer jacket. It is rated 600 V (TC-ER), 150 V (NPLF) and 90°C Dry, 90°C Wet, with indoor/outdoor suitability including sunlight resistance and burial.
Belden 1070A 010 Key Features
- Supports industrial control and instrumentation wiring in raceways, cable trays, and ducts.
- Uses 4 pair 16 AWG (7x24) BC - bare copper stranded conductors for control and instrumentation circuits.
- Includes PVC/Nylon - polyvinyl chloride + nylon insulation with ICEA Chart E1 color coding for consistent identification.
- Provides an overall Beldfoil® shield with 100% coverage and a 16 AWG (7x24) TC drainwire for noise rejection.
- Finished with a black PVC - polyvinyl chloride outer jacket and includes a ripcord.
- Rated 600 V (TC-ER), 150 V (NPLF) and 90°C Dry, 90°C Wet.
- Environmental suitability includes indoor/outdoor, sunlight resistance, and burial.
Belden 1070A 010 Applications
- Use in industrial control systems where reliable signal and control wiring is needed.
- Install in raceways, cable trays, and ducts in industrial environments.
- Support digital control and low voltage digital control (24v, …) circuits.
- Connect instrumentation, including Instruments (4-20ma, 0-10v, ...).
- Pair with encoders and other feedback devices in control circuits.
- Meet distributed control system (DCS) and programmable logic controller (PLC) wiring needs.
- Connect field devices such as Solenoids, Valves, Actuators, and Positioners.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 4 |
| Element type | pair(s) |
| Conductor Type | stranded conductor |
| Insulation thickness (nom.) | 0.022 in (0.56 mm) |
| Insulation diameter (nom.) | 0.101 in (2.57 mm) |
| Shield Type | tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Jacket thickness (nom.) | 0.064 in (1.6 mm) |
| Overall cable diameter (nom.) | 0.554 in (14.1 mm) |
| Armor | No |
| Bulk cable weight | 163 lbs/1000ft |
| Nom. conductor DCR | 4.36 Ohm/1000ft |
| Max. current | 13 Amps per Conductor @ 30°C |
| Nom. outer shield DCR | 3.14 Ohm/1000ft (10.3 Ohm/km) |
| Operating temperature | -30°C to 90°C Dry/Wet |
| Stationary min. bend radius | 6.6 in (170 mm) |
| Installation min. bend radius | 6.6 in (170 mm) |
| Max Pull Tension | 321 lbs (146 kg) |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC-ER |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.