Belden 1071A 010, Power Limited Tray Cable 16 AWG 8 Pairs 600V PVC, Black Jacket

Description
Belden 1071A 010 is a power limited tray cable designed for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It is built with 8 pair 16 AWG (7x24) BC - Bare Copper stranded conductors, PVC/Nylon - Polyvinyl Chloride + Nylon insulation, and an overall Beldfoil® Shield. UL Voltage Rating is 600 V (TC-ER), 150 V (NPLF), with UL temperature of 90°C Dry, 90°C Wet. The black PVC - Polyvinyl Chloride outer jacket includes a ripcord and is listed for indoor/outdoor use, including burial and sunlight resistance.
Belden 1071A 010 Key Features
- Power limited tray cable construction for industrial control and instrumentation wiring in raceways, cable trays, and ducts.
- 8 pair conductors using 16 AWG (7x24) BC - Bare Copper stranded conductor design.
- PVC/Nylon - Polyvinyl Chloride + Nylon insulation with ICEA Chart E1 color code.
- Overall Beldfoil® Shield with tape construction, Bi-Laminate (Alum+Poly) material, and 100% coverage.
- UL Voltage Rating: 600 V (TC-ER), 150 V (NPLF).
- UL temperature: 90°C Dry, 90°C Wet.
- PVC - Polyvinyl Chloride outer jacket in black with ripcord: Yes.
- Environmental suitability includes indoor/outdoor, indoor, outdoor, sunlight resistance, burial.
Belden 1071A 010 Applications
- Used in industrial control systems where signal and control circuits are routed through raceways, cable trays, and ducts.
- Supports digital control wiring in control circuits where consistent signal handling is required.
- Applied in instrumentation runs, including Instruments (4-20ma, 0-10v, ...), to connect field devices to control equipment.
- Suitable for low voltage digital control (24v, …) connections in automation and control panels.
- Used with encoders to carry control and feedback signals between devices.
- Commonly installed in distributed control system (DCS) architectures to interconnect control and instrumentation points.
- Used in programmable logic controller (PLC) systems to link I/O and control circuits.
- Connects Solenoids, Valves, Actuators, and Positioners within control circuits.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 8 |
| Element type | pair(s) |
| Conductor Type | Stranded Conductor |
| Insulation thickness (nom.) | 0.022 in (0.56 mm) |
| Insulation diameter (nom.) | 0.101 in (2.57 mm) |
| Shield | Yes - this has a shield |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire type | 16 AWG (7x24) TC |
| Shield description | Overall Beldfoil® Shield |
| Armor | No |
| Jacket thickness (nom.) | 0.064 in (1.6 mm) |
| Overall cable diameter (nom.) | 0.666 in (16.9 mm) |
| Bulk cable weight | 267 lbs/1000ft |
| Conductor DCR (nom.) | 4.36 Ohm/1000ft |
| Outer shield DCR (nom) | 3.01 Ohm/1000ft (9.88 Ohm/km) |
| Max. current | 9 Amps per Conductor @ 30°C |
| Operating temperature | -30°C to 90°C Dry/Wet |
| Bend radius (stationary min.) | 8.0 in (200 mm) |
| Bend radius (installation min.) | 8.0 in (200 mm) |
| Max Pull Tension | 607 lbs (275 kg) |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC-ER |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |