Belden 1079A 010, Power Limited Tray Cable 16PR 20 AWG 300V PVC, Black Jacket

SKU:Belden 1079A
● In stock
Description
Belden 1079A 010 is a power limited tray cable for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It is built with 16 twisted pairs of 20 AWG (7x28) BC - Bare Copper conductors with PVC - Polyvinyl Chloride insulation, plus 1 communication wire of 22 AWG (7x30) BC - Bare Copper. For noise rejection in control circuits, each pair is individually shielded, and the cable also includes an overall Beldfoil® shield with 100% coverage. A black PVC - Polyvinyl Chloride outer jacket with sunlight resistance supports indoor/outdoor use, with ratings including PLTC ITC CMG and UL AWM 2464.
Belden 1079A 010 Key Features
- Power limited tray cable designed for industrial control and instrumentation wiring in raceways, cable trays, and ducts.
- 16 twisted pairs of 20 AWG (7x28) BC - Bare Copper conductors, plus 1 communication wire of 22 AWG (7x30) BC - Bare Copper.
- Shielding includes individual pair shields and an overall Beldfoil® shield, each with 100% coverage, to support noise rejection in control circuits.
- Black PVC - Polyvinyl Chloride outer jacket with sunlight resistance for indoor/outdoor use.
- Ratings and designations include PLTC ITC CMG and UL AWM 2464.
Belden 1079A 010 Applications
- Use it for industrial control wiring where organized routing through raceways, cable trays, and ducts is required.
- Support digital control and low voltage digital control (24v, …) connections in control systems with this cable.
- Run instruments (4-20ma, 0-10v, ...) and other instrumentation signal wiring in industrial environments.
- Choose it for control circuits that benefit from noise rejection.
- Apply it in distributed control system (DCS) and programmable logic controller (PLC) installations.
- Connect encoders, solenoids, valves, actuators, and positioners in control and instrumentation setups.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Pairs | 16 |
| Pair Conductor Size | 20 AWG |
| Pair Stranding | 7x28 |
| Pair Conductor Material | BC - Bare Copper |
| Comm Wire(s) | 1 |
| Comm Wire size | 22 AWG |
| Comm Wire stranding | 7x30 |
| Comm Wire material | BC - Bare Copper |
| Conductor Type | Stranded Conductor |
| Ripcord | Yes |
| Armor | No |
| Insulation Material | PVC - Polyvinyl Chloride |
| Pair insulation nominal thickness | 0.018 in (0.46 mm) |
| Pair color code | Black, White and Numbered |
| Comm wire insulation nominal thickness | 0.019 in (0.48 mm) |
| Comm Wire color | Orange |
| Individual pair shield | Tape |
| Individual pair shield material | Bi-Laminate (Alum+Poly) |
| Individual pair shield coverage | 100% |
| Individual pair drainwire | 22 AWG (7x30) TC |
| Overall shield | Tape |
| Overall shield material | Bi-Laminate (Alum+Poly) |
| Overall shield coverage | 100% |
| Overall drainwire | 20 AWG (7x28) TC |
| Shield Type | Both individual and overall shields |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Outer jacket nominal thickness | 0.063 in (1.6 mm) |
| Overall cable diameter (nominal) | 0.704 in (17.9 mm) |
| Bulk cable weight | 286 lbs/1000ft |
| UL Voltage Rating | 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC) |
| Pair nominal Conductor DCR | 9.5 Ohm/1000ft (31 Ohm/km) |
| Pair nominal capacitance Cond-to-Cond | 30 pF/ft (98 pF/m) |
| Pair nominal capacitance (Cond-to-Shield) | 55 pF/ft (180 pF/m) |
| Pair nominal inductance | 0.19 µH/ft (0.62 µH/m) |
| Max. current | 3 Amps per Conductor @ 25°C |
| Comm Wire nominal Conductor DCR | 14.7 Ohm/1000ft (48.2 Ohm/km) |
| Nom. outer shield DCR | 6.5 Ohm/1000ft (21 Ohm/km) |
| UL temperature | 105°C |
| Operating temperature | -30°C to +105°C |
| Bend radius (stationary min.) | 7.0 in (180 mm) |
| Bend radius (installation min.) | 7.0 in (180 mm) |
| Max Pull Tension | 617 lbs (280 kg) |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance |
| Flammability / reaction to fire | UL1685 (FT4 Loading), FT4, T-29-520, 1202 |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| UL instrumentation print | UL instrumentation, 16 Pair 20+22AWG (7x28) Bare Copper, PVC Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, Black PVC Outer Jacket, PLTC ITC CMG AWM 2464 SUN RES |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.