Contact1-800-975-3686
Ramcorp Wire & Cable

Belden 1086A 010, Power Limited Tray Cable 24C 20 AWG 300V PVC Jacket, Black Jacket

Belden 1086A 010

SKU:Belden 1086A

$2,932.80

In stock

Description

Specifications

Belden 1086A 010, Power Limited Tray Cable 24C 20 AWG 300V PVC Jacket, Black Jacket specifications
AttributeValue
Conductor TypeStranded conductor
TriadsTriad(s): 24
Triad size20 AWG
Triad stranding7x28
Triad materialBC - Bare Copper
Communication wire(s)Comm Wire(s): 1
Comm Wire size22 AWG
Comm Wire stranding7x30
Comm Wire materialBC - Bare Copper
Triad insulationPVC - Polyvinyl Chloride
Triad insulation thickness (nom.)0.018 in (0.46 mm)
Triad color codeBlack, White, Red and Numbered
Comm wire insulationPVC - Polyvinyl Chloride
Comm wire insulation thickness (nom.)0.019 in (0.48 mm)
Comm wire color codeOrange
ShieldingYes - this has a shield
Shield TypeBoth individual and overall shields
Inner shield (triads) typeTape
Inner shield (triads) materialBi-Laminate (Alum+Poly)
Inner shield (triads) coverage100%
Inner shield (triads) drainwire type22 AWG (7x30) TC
Inner shield (comm wire) typeNo Shield
Outer shield typeTape
Outer shield materialBi-Laminate (Alum+Poly)
Outer shield coverage100%
Outer Shield drainwire type20 AWG (7x28) TC
Nom. outer shield DCR16 Ohm/1000ft (52 Ohm/km)
Outer jacket materialPVC - Polyvinyl Chloride
Outer jacket thickness (nom.)0.074 in (1.9 mm)
Overall cable diameter (nominal)1.079 in (27.41 mm)
Jacket ColorBlack
Outer jacket ripcordYes
ArmorNo
Triad conductor DCR (nom.)9.5 Ohm/1000ft (31 Ohm/km)
Triad capacitance, Cond-to-Cond (nom.)30 pF/ft (98 pF/m)
Triad capacitance, Cond-to-Shield (nom.)55 pF/ft (180 pF/m)
Triad inductance (nom.)0.19 µH/ft (0.62 µH/m)
Triad max current3 Amps per conductor @ 25°C
Comm wire conductor DCR (nom.)14.7 Ohm/1000ft (48.2 Ohm/km)
Stationary min. bend radius10.8 in (274 mm)
Installation min. bend radius10.8 in (274 mm)
Max Pull Tension1250 lbs (567 kg)
Bulk cable weight607 lbs/1000ft
Environmental suitabilityIndoor/Outdoor, Indoor, Outdoor, Sunlight Resistance
Flammability / reaction to fireUL1685 (FT4 Loading), FT4, T-29-520, 1202
NEC / UL complianceArticle 725, Article 727, Article 800, CMG, ITC, PLTC
AWM complianceAWM 2464
CEC / C(UL) complianceCMG
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC complianceChina RoHS II (GB/T 26572-2011)
Item TypeBelden Instrumentation Cable
Priced PerFT

Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.

Need a cut length, bulk pricing, or a spec sheet?

Our team quotes custom lengths and volume orders, usually same day.