Belden 1089A 010, Power Limited Tray Cable 36PR 16 AWG 600V PVC, Black Jacket

SKU:Belden 1089A
● In stock
Description
Belden 1089A 010 is a power limited tray cable for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It is built with 36 pair 16 AWG (7x26) bare copper conductors and PVC-NYL insulation, using E1 color code with black, white and numbered conductor identification for organized pair identification. An overall Beldfoil® shield with 100% coverage supports noise reduction in signal and control circuits. Electrical ratings include 600 V (TC-ER) and 150 V (NPLF), with a black PVC outer jacket and UL temperature of 90°C dry, 75°C wet.
Belden 1089A 010 Key Features
- The 36 pair construction supports multi-signal control and instrumentation wiring in a single run.
- 16 AWG (7x26) bare copper conductors use a stranded conductor design for flexible installation handling.
- PVC-NYL insulation with E1 color code and black, white and numbered identification helps keep pairs organized during termination.
- An overall Beldfoil® shield (tape) with 100% coverage and bi-laminate (Alum+Poly) construction supports noise reduction in signal and control circuits.
- UL voltage rating: 600 V (TC-ER), 150 V (NPLF).
- A black PVC outer jacket lists environmental suitability as indoor/outdoor, indoor, outdoor, sunlight resistance, burial.
- UL temperature: 90°C dry, 75°C wet.
Belden 1089A 010 Applications
- Used for industrial control and instrumentation wiring in raceways, cable trays, and ducts.
- Supports digital control and control circuits where organized pair identification is needed during installation and termination.
- Common applications include distributed control system (DCS) and programmable logic controller (PLC) signal and control circuits.
- Suitable for instruments (4-20ma, 0-10v, ...) and low voltage digital control (24v, …) connections.
- Applied in encoder wiring and for control of devices such as solenoids, valves, actuators, and positioners.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 36 |
| Element type | pair(s) |
| Conductor Type | stranded conductor |
| Insulation thickness (nominal) | 0.022 in (0.56 mm) |
| Insulation diameter (nominal) | 0.101 in (2.57 mm) |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 16 AWG (7x24) TC |
| Ripcord | Yes |
| Armor | No |
| Thermocouple | No |
| Jacket thickness (nominal) | 0.084 in (2.1 mm) |
| Cable diameter (nominal) | 1.297 in (32.94 mm) |
| Bulk cable weight | 1020 lbs/1000ft |
| Nom. conductor DCR | 3.67 Ohm/1000ft (12.0 Ohm/km) |
| Nom. outer shield DCR | 2.95 Ohm/1000ft (9.68 Ohm/km) |
| Operating temperature | -30C to 90C Dry, 75C wet |
| Bend radius (stationary min.) | 15.6 in (396 mm) |
| Bend radius (installation min.) | 15.6 in (396 mm) |
| Max Pull Tension | 2606 lbs (1182 kg) |
| Sunlight resistance | SUN RES |
| Direct Burial | DIR BUR |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC-ER |
| Flammability / reaction to fire | UL1685 (FT4 Loading), FT4, 1202 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |