Belden 1094A 010, Triad 8 FS TRP 18 AWG 600V PVC NYL FS PVC

SKU:Belden 1094A
● In stock
Description
Belden 1094A 010 is a UL instrumentation cable with 8 triad 18 AWG (7x26) BC - Bare Copper conductors and PVC/Nylon - Polyvinyl Chloride + Nylon insulation. It features individual & overall Beldfoil® shield tape with 100% coverage and includes drainwires to support noise reduction in sensitive circuits. The cable has a black PVC - Polyvinyl Chloride outer jacket and is rated for Indoor, Outdoor, Sunlight Resistance, UV Resistance, and Burial. UL Voltage Rating is 600 V (TC-ER), 150 V (NPLF), with UL Temperature of 90°C Dry/Wet and an operating range of -20°C to +90°C.
Belden 1094A 010 Key Features
- 8 triad 18 AWG (7x26) BC - Bare Copper conductors for instrumentation and control wiring.
- PVC/Nylon - Polyvinyl Chloride + Nylon insulation with ICEA Chart E1 color coding for consistent identification.
- Individual & overall Beldfoil® shield tape with 100% coverage, plus drainwires, to support noise reduction in sensitive circuits.
- Black PVC - Polyvinyl Chloride outer jacket with environmental suitability for Indoor, Outdoor, Sunlight Resistance, UV Resistance, and Burial.
- UL Voltage Rating: 600 V (TC-ER), 150 V (NPLF).
- UL Temperature: 90°C Dry/Wet; operating: -20°C to +90°C.
Belden 1094A 010 Applications
- It is used in industrial control and control circuits where instrumentation and control signals are required.
- Installation is supported in raceways, cable trays, and ducts for organized routing in industrial environments.
- It is suitable for digital control and low voltage digital control (24v, …) signal wiring.
- Instruments (4-20ma, 0-10v, ...) can be wired where consistent signal transmission is needed.
- RTD connections are supported in instrumentation systems.
- It is suitable for distributed control system (DCS) and programmable logic controller (PLC) installations.
- It is used for wiring to Solenoids, Valves, actuators, positioners in control and automation systems.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Element | Triad(s) |
| No. of elements | 8 |
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Insulation thickness (nom.) | 0.022 in (0.56 mm) |
| Insulation diameter (nom.) | 0.088 in (2.2 mm) |
| Color Code | ICEA Chart E1 |
| Separator | Polyester Tape |
| Ripcord | Yes |
| Inner shield type | Tape |
| Inner shield material | Bi-Laminate (Alum+Poly) |
| Inner shield coverage | 100% |
| Inner shield drainwire | 20 AWG (7x28) TC |
| Outer shield type | Tape |
| Outer shield material | Bi-Laminate (Alum+Poly) |
| Outer shield coverage | 100% |
| Outer shield drainwire | 18 AWG (7x26) TC |
| Jacket thickness (nom.) | 0.064 in (1.6 mm) |
| Overall cable diameter (nominal) | 0.755 in |
| Bulk cable weight | 311 lbs/1000ft |
| Nom. conductor DCR | 6.7 Ohm/1000ft |
| Nom. inner shield DCR | 7.11 Ohm/1000ft (23.3 Ohm/km) |
| Nom. outer shield DCR | 4.8 Ohm/1000ft (16 Ohm/km) |
| Max. current | 7 Amps per Conductor at 30ºC |
| Bend radius (stationary min.) | 3.02 in (76.7 mm) |
| Bend radius (installation min.) | 3.775 in |
| Max Pull Tension | 672 lbs (305 kg) |
| Flammability / reaction to fire | UL1685 UL Loading, FT4, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, Article 760 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |