Belden 1097A 010, Power Limited Tray Cable 4 Triads 16 AWG 600V PVC, Black Jacket

SKU:Belden 1097A
● In stock
Description
Belden 1097A 010 is a power limited tray cable for industrial control and instrumentation circuits where reliable signal integrity is critical. It features 4 triads of 16 AWG (7x24) BC - Bare Copper stranded conductors with PVC/Nylon - Polyvinyl Chloride + Nylon insulation and ICEA Chart E1 color coding. For noise protection, each triad is individually shielded, and the cable also includes an overall Beldfoil® shield under a black PVC - Polyvinyl Chloride outer jacket. UL Voltage Rating is 600 V (TC-ER), 150 V (NPLF), and it is suitable for use in raceways, cable trays, and ducts, including DCS and PLC applications.
Belden 1097A 010 Key Features
- Built with 4 triads of 16 AWG (7x24) BC - Bare Copper stranded conductors for industrial control and instrumentation circuits.
- PVC/Nylon - Polyvinyl Chloride + Nylon insulation with ICEA Chart E1 color coding for consistent conductor identification.
- Shielding includes an individual shield on each triad plus an overall Beldfoil® shield for noise protection.
- Black PVC - Polyvinyl Chloride outer jacket with Ripcord: Yes and Armor: No.
- UL Voltage Rating: 600 V (TC-ER), 150 V (NPLF).
Belden 1097A 010 Applications
- Used in industrial control and control circuits where dependable signal integrity is required.
- Suitable for installation in raceways, cable trays, and ducts.
- Supports digital control and low voltage digital control (24v, …) connections in control systems.
- Commonly used for instruments (4-20ma, 0-10v, ...) and RTD signal wiring.
- Applied in distributed control system (DCS) and programmable logic controller (PLC) applications.
- Can be applied to solenoids and to field devices such as valves, actuators, and positioners.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Element type | Triad(s) |
| Number of elements | 4 |
| Conductor Type | Stranded conductor |
| Insulation thickness (nom.) | 0.022 in (0.56 mm) |
| Insulation diameter (nom.) | 0.101 in (2.57 mm) |
| Inner shield (each triad) | Tape; Bi-Laminate (Alum+Poly); 100% coverage; drainwire 18 AWG (7x26) TC |
| Outer shield | Tape; Bi-Laminate (Alum+Poly); 100% coverage; drainwire 16 AWG (7x24) TC |
| Jacket thickness (nom.) | 0.064 in (1.6 mm) |
| Overall cable diameter (nom.) | 0.646 in (16.4 mm) |
| Nom. conductor DCR | 4.36 Ohm/1000ft |
| Nom. inner shield DCR | 4.99 Ohm/1000ft (16.4 Ohm/km) |
| Nom. outer shield DCR | 3.07 Ohm/1000ft (10.1 Ohm/km) |
| Max. current | 9 Amps per Conductor @ 30°C |
| UL temperature | 90°C Dry, 90°C Wet |
| Operating temperature | -30°C to 90°C Dry/Wet |
| Bend radius (stationary min.) | 7.8 in (200 mm) |
| Bend radius (installation min.) | 7.8 in (200 mm) |
| Max Pull Tension | 487 lbs (221 kg) |
| Bulk cable weight | 245 lbs/1000ft |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC-ER |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |