Belden 1152A A8R, Coax CATV 18 AWG Duofoil + TC Braid FEP

SKU:Belden 1152A
● In stock
Description
Belden 1152A A8R is an RG type: 6 coaxial cable with an 18 AWG solid BCCS - Bare Copper Covered Steel conductor, FEP - Fluorinated Ethylene Propylene (Foam) insulation, and an FEP - Fluorinated Ethylene Propylene jacket. It features a Quad Shield (F/B+F/B) design and a nominal characteristic impedance of 75 Ohm for broadband signal distribution. The cable is plenum-rated with CMP listing and includes electrical performance details such as 82% nominal velocity of propagation and 20 dB min. structural return loss from 10 - 400 MHz.
Belden 1152A A8R Key Features
- RG type: 6 coaxial construction with a nominal characteristic impedance of 75 Ohm.
- 18 AWG solid BCCS - Bare Copper Covered Steel conductor with a nominal diameter of 0.040 in.
- FEP - Fluorinated Ethylene Propylene (Foam) insulation with White color code.
- Quad Shield (F/B+F/B) construction using tape and braid layers for enhanced shielding coverage.
- FEP - Fluorinated Ethylene Propylene jacket with a nominal overall cable diameter of 0.273 in (6.93 mm).
- Plenum-rated with NEC / UL compliance: Article 800, CMP and flammability / reaction to fire: NFPA 262, FT6.
Belden 1152A A8R Applications
- Use it for broadband signal distribution where consistent 75 Ohm performance is required.
- Choose it for Cable Television (CATV) connectivity in building and distribution runs.
- Install it for RF drop Cable applications where dependable signal delivery is needed.
- Connect Over-The-Air (OTA) antennas to receiving equipment with this cable.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Shield layers | Layer 1: Tape, Tri-Laminate (Alum+Poly+Alum), Duobond® II, 100%; Layer 2: Braid, Tinned Copper (TC), 60%; Layer 3: Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100%; Layer 4: Braid, Tinned Copper (TC), 45% |
| Nom. insulation diameter | 0.170 in (4.32 mm) |
| Bulk cable weight | 45 lbs/1000ft |
| Nom. capacitance (Cond-to-Shield) | 16.5 pF/ft (54.1 pF/m) |
| Nom. conductor DCR | 28 Ohm/1000ft (92 Ohm/km) |
| Nom. outer shield DCR | 1.8 Ohm/1000ft (5.9 Ohm/km) |
| UL Voltage Rating | 300 V (CMP), (CMP) |
| Return loss | 10 - 400 MHz: 20 dB min. structural return loss |
| Nom. velocity of prop. | 82% |
| Nominal attenuation | 1 MHz: 0.3 dB/100ft; 10 MHz: 0.66 dB/100ft; 50 MHz: 1.6 dB/100ft; 100 MHz: 2.2 dB/100ft; 200 MHz: 3.0 dB/100ft; 400 MHz: 4.6 dB/100ft; 700 MHz: 6.6 dB/100ft; 900 MHz: 7.7 dB/100ft; 1000 MHz: 8.2 dB/100ft |
| Operating temperature | -70°C to +200°C |
| UL temperature | 200°C |
| Stationary min. bend radius | 2.75 in (69.9 mm) |
| Installation min. bend radius | 2.75 in (69.9 mm) |
| Max Pull Tension | 192 lbs (87.1 kg) |
| Environmental suitability | Indoor - Plenum, Indoor, Outdoor, Aerial - When supported by messenger Wire, Burial |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca |
| Other standard compliance(s) | ANSI/SCTE 74 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Item Type | Belden Coaxial Cable RG6 |
| Other Part Numbers | 1152A A8R1000, 1152A A8R, 1152A A8R100, 1152A A8R250, 1152A A8R500, 1152A |
| Priced Per | FT |