Belden 1420A 060, Multi Conductor Computer Cable 3 Pair 24 AWG PVC

SKU:Belden 1420A
● In stock
Description
Belden 1420A 060 is a multi conductor computer EIA RS-232/422 cable with 3 twisted pairs of 24 AWG stranded (7x32) TC - Tinned Copper conductors. It uses Datalene® insulation and an overall Beldfoil® shield (100% coverage) with a 24 AWG (7x32) TC drain wire. This indoor cable is jacketed in PVC - Polyvinyl Chloride with a Chrome jacket color and a 0.261 in (6.63 mm) nominal overall diameter. It is rated UL 1685 FT4 Loading, IEC 60332-1-2, and UL Voltage Rating: 300 V (CM), 30 V (UL AWM 2919).
Belden 1420A 060 Key Features
- 3 twisted pairs built with 24 AWG stranded (7x32) TC - Tinned Copper conductors.
- Datalene® insulation with PE - Polyethylene (Foam) insulation material.
- Overall Beldfoil® tape shield with Bi-Laminate (Alum+Poly) material and 100% coverage, plus a 24 AWG (7x32) TC drain wire.
- PVC - Polyvinyl Chloride jacket in Chrome with a 0.261 in (6.63 mm) nominal overall cable diameter.
- Environmental suitability: Indoor (Not Riser or Plenum), Indoor.
- UL Voltage Rating: 300 V (CM), 30 V (UL AWM 2919).
Belden 1420A 060 Applications
- Supports RS-232 extended distance applications where consistent communications are needed over longer runs.
- Works for RS-423 applications in communications and control systems.
- Enables computer communications between connected equipment.
- Carries low voltage analog signals (4-20ma, 0-10v, ...) in control and monitoring circuits.
- Handles low voltage digital control (24v, …) for control signaling.
- Can be used for line level audio signal connections.
- Fits panel wiring inside indoor installations.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Color Code | Western Electric Standard |
| Insulation thickness (nom.) | 0.013 in (0.33 mm) |
| Insulation diameter (nom.) | 0.049 in (1.2 mm) |
| Jacket thickness (nom.) | 0.035 in (0.89 mm) |
| Bulk cable weight | 30 lbs/1000ft |
| Conductor DCR (nom.) | 24 Ohm/1000ft |
| Capacitance, Cond-to-Cond (nom.) | 13 pF/ft (43 pF/m) |
| Capacitance, Cond-to-other (nom.) | 22 pF/ft (72 pF/m) |
| Characteristic impedence (nom.) | 100 Ohm |
| Inductance (nom.) | 0.213 µH/ft (0.699 µH/m) |
| Velocity of prop. (nom.) | 78% |
| Max. current | 1.8 Amps per conductor at 25ºC |
| Outer shield DCR (nom) | 15.1 Ohm/1000ft (49.5 Ohm/km) |
| UL temperature | 80°C |
| Operating temperature | -20°C to +80°C |
| Bend radius (stationary min.) | 2.6 in (66 mm) |
| Bend radius (installation min.) | 2.6 in (66 mm) |
| Max Pull Tension | 33 lbs (15 kg) |
| Flammability / reaction to fire | UL 1685 FT4 Loading, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CM |
| AWM compliance | AWM 2919 |
| CEC / C(UL) compliance | CM |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Multi-Pair Cable |
| Priced Per | FT |