Belden 1466A 010, Power Limited Tray Cable 4PR 18 AWG 300V PVC, Black Jacket

SKU:Belden 1466A
● In stock
Description
Belden 1466A 010 is a power-limited tray cable for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It is built with 4 twisted pairs of 18 AWG (7x26) BC - Bare Copper conductors plus 1 22 AWG (7x30) BC - Bare Copper comm wire, with PVC - Polyvinyl Chloride insulation and an overall Beldfoil® shield. The cable has a black PVC - Polyvinyl Chloride outer jacket with ripcord and is rated 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC) with an operating temperature of -30°C to +105°C.
Belden 1466A 010 Key Features
- Power-limited tray cable design for industrial control and instrumentation wiring in raceways, cable trays, and ducts.
- 4 twisted pairs of 18 AWG (7x26) BC - Bare Copper conductors plus 1 22 AWG (7x30) BC - Bare Copper comm wire.
- PVC - Polyvinyl Chloride insulation with an overall Beldfoil® shield (Tape, Bi-Laminate (Alum+Poly), 100% coverage) for noise protection.
- Black PVC - Polyvinyl Chloride outer jacket with ripcord for easier installation.
- UL voltage rating: 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC); operating temperature: -30°C to +105°C.
Belden 1466A 010 Applications
- Supports industrial control and instrumentation wiring routed through raceways, cable trays, and ducts.
- Commonly used in distributed control system (DCS) and programmable logic controller (PLC) installations.
- Fits instrument signal wiring such as Instruments (4-20ma, 0-10v, ...) and low voltage digital control (24v, …).
- Connects encoders and other digital control connections in control networks.
- Used in control circuits for Solenoids, Valves, Actuators, and Positioners.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Pairs | 4 |
| Pair Conductor Size | 18 AWG |
| Pair Stranding | 7x26 |
| Pair Conductor Material | BC - Bare Copper |
| Comm Wire(s) | 1 |
| Comm Wire size | 22 AWG |
| Comm Wire stranding | 7x30 |
| Comm Wire material | BC - Bare Copper |
| Conductor Type | Stranded Conductor |
| Drainwire type | 18 AWG (7x26) TC |
| Inner shield (comm wire) | No Shield |
| Pair insulation thickness (nominal) | 0.017 in (0.43 mm) |
| Pair color code | Black, White and Numbered |
| Comm wire insulation thickness (nominal) | 0.019 in (0.48 mm) |
| Comm Wire color | Orange |
| Outer jacket thickness (nominal) | 0.053 in (1.3 mm) |
| Overall cable diameter (nominal) | 0.470 in (11.9 mm) |
| Ripcord | Yes |
| Armor | No |
| Nom. Conductor DCR (pairs) | 5.86 Ohm/1000ft (19.2 Ohm/km) |
| Nom. conductor DCR (comm wire(s)) | 14.7 Ohm/1000ft (48.2 Ohm/km) |
| Nom. outer shield DCR | 4.75 Ohm/1000ft (15.6 Ohm/km) |
| UL temperature | 105°C |
| Bend radius (stationary min.) | 4.7 in (120 mm) |
| Bend radius (installation min.) | 4.7 in (120 mm) |
| Max Pull Tension | 211 lbs (95.7 kg) |
| Bulk cable weight | 106.3 lbs/1000ft |
| Flammability / reaction to fire | UL1685 (FT4 Loading), FT4, 1202 |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial |
| UL/NEC compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Manufacturer markings | PLTC ITC CMG AWM 2464 SUN RES |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?