Belden 1467A 010 is a power limited tray cable for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It features 8 pair 18 AWG (7x26) bare copper conductors plus 1 22 AWG (7x30) bare copper comm wire with PVC insulation and ICEA Chart E1 color coding. For noise reduction in control circuits, it uses an overall Beldfoil® shield with 100% coverage and an 18 AWG (7x26) TC drainwire under a black PVC outer jacket with ripcord. Rated 300 V (PLTC, CMG, AWM 2464), 150 V (ITC) and 105°C.
Belden 1467A 010 Key Features
- 8 pair 18 AWG (7x26) BC - bare copper conductors plus 1 22 AWG (7x30) BC - bare copper comm wire.
- PVC - polyvinyl chloride insulation with ICEA Chart E1 pair color code and orange comm wire color.
- Overall Beldfoil® shield with 100% coverage and 18 AWG (7x26) TC drainwire for noise reduction in control circuits.
- Black PVC - polyvinyl chloride outer jacket with ripcord.
- UL voltage rating: 300 V (PLTC, CMG, AWM 2464), 150 V (ITC); UL temperature: 105°C.
Belden 1467A 010 Applications
- Use for industrial control wiring where a power limited tray cable is specified.
- Install in raceways, cable trays, and ducts.
- Support digital control and control circuits where noise reduction is important.
- Pair with instruments (4-20ma, 0-10v, ...) and low voltage digital control (24v, …).
- Apply in distributed control system (DCS) and programmable logic controller (PLC) installations.
- Connect encoders, solenoids, valves, actuators, and positioners in industrial systems.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of pairs | 8 |
| Conductor Type | Stranded Conductor |
| Comm Wire count | 1 |
| Pair insulation thickness | 0.017 in (0.43 mm) |
| Pair nominal Insulation Diameter | 0.080 in (2.0 mm) |
| Comm Wire insulation thickness | 0.019 in (0.48 mm) |
| Comm wire nominal insulation diameter | 0.066 in (1.7 mm) |
| Overall shield type | Tape |
| Overall shield material | Bi-Laminate (Alum+Poly) |
| Comm Wire inner shield | No Shield |
| Nominal jacket thickness | 0.053 in (1.3 mm) |
| Overall cable diameter (nominal) | 0.567 in (14.4 mm) |
| Armor | No |
| Pair nominal Conductor DCR | 6.66 Ohm/1000ft |
| Pair max. current | 7 Amps per Conductor @ 30°C |
| Comm Wire nominal Conductor DCR | 17.2 Ohm/1000ft (56.4 Ohm/km) |
| Comm wire max. current | 9.6 Amps per Conductor @ 30°C |
| Nom. outer shield DCR | 4.47 Ohm/1000ft (14.7 Ohm/km) |
| Operating Temperature Range | -30°C to +105°C |
| Bend radius (stationary min.) | 6.8 in (170 mm) |
| Bend radius (installation min.) | 6.8 in (170 mm) |
| Max Pull Tension | 390 lbs (180 kg) |
| Bulk cable weight | 176 lbs/1000ft |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Manufacturer description | UL Instrumentation, 8 Pair 18+22AWG (7x26+7x30) Bare Copper, PVC Insulation E1 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, PLTC ITC CMG AWM 2464 SUN RES |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.