Belden 1468A 010, Power Limited Tray Cable 12PR 18 AWG 300V PVC, Black Jacket

SKU:Belden 1468A
● In stock
Description
Belden 1468A 010 is a power-limited tray cable designed for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It features 12 twisted pairs of 18 AWG (7x26) BC - Bare Copper conductors plus 1 comm wire of 22 AWG (7x30) BC - Bare Copper, with PVC - Polyvinyl Chloride insulation and a black PVC - Polyvinyl Chloride outer jacket. For noise reduction in control circuits, it includes an overall Beldfoil® Shield with 100% coverage and an 18 AWG (7x26) TC drainwire. UL Voltage Rating is 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC), and environmental suitability includes Indoor/Outdoor, Sunlight Resistance, and Burial.
Belden 1468A 010 Key Features
- 12 twisted pairs plus 1 comm wire support multi-signal control and instrumentation wiring.
- 18 AWG (7x26) BC - Bare Copper pair conductors with a 22 AWG (7x30) BC - Bare Copper comm wire.
- PVC - Polyvinyl Chloride insulation with black, white and numbered pair color code, plus an orange comm wire color.
- Overall Beldfoil® Shield (Tape, Bi-Laminate (Alum+Poly)) with 100% coverage and an 18 AWG (7x26) TC drainwire.
- Black PVC - Polyvinyl Chloride outer jacket with Ripcord: Yes and Armor: No.
- UL Voltage Rating: 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC).
- Environmental suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial.
Belden 1468A 010 Applications
- Supports industrial control and digital control wiring where multiple control and instrumentation signals are routed together.
- Installs in raceways, cable trays, and ducts for organized routing in industrial environments.
- Works with instruments (4-20ma, 0-10v, ...) and low voltage digital control (24v, …) signal circuits.
- Fits distributed control system (DCS) and programmable logic controller (PLC) installations.
- Commonly used in control circuits for devices such as solenoids, valves, actuators, positioners, and encoders.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor Type | Stranded Conductor |
| Pair insulation thickness (nominal) | 0.017 in (0.43 mm) |
| Comm wire insulation thickness (nominal) | 0.019 in (0.48 mm) |
| Inner shield (comm wire) | No Shield |
| Outer jacket thickness (nominal) | 0.063 in (1.6 mm) |
| Overall cable diameter (nominal) | 0.699 in (17.8 mm) |
| Bulk cable weight | 258.6 lbs/1000ft |
| Nom. Conductor DCR (pairs) | 5.86 Ohm/1000ft (19.2 Ohm/km) |
| Nom. conductor DCR (comm wire(s)) | 14.7 Ohm/1000ft (48.2 Ohm/km) |
| Nom. outer shield DCR | 4.22 Ohm/1000ft (13.8 Ohm/km) |
| UL temperature | 105°C |
| Operating temperature | -30°C to +105°C |
| Bend radius (stationary min.) | 7.0 in (180 mm) |
| Bend radius (installation min.) | 7.0 in (180 mm) |
| Max Pull Tension | 560 lbs (250 kg) |
| Flammability / reaction to fire | UL1685 (FT4 Loading), FT4, 1202 |
| Thermocouple | No |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.