Belden 1471A 010, Power Limited Tray Cable 24PR 18 AWG 300V PVC, Black Jacket

SKU:Belden 1471A
● In stock
Description
Belden 1471A 010 is a power limited tray cable for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It is built with 24 twisted pairs of 18 AWG (7x26) BC - Bare Copper conductors plus 1 x 22 AWG (7x30) BC - Bare Copper comm wire, with PVC - Polyvinyl Chloride insulation and a black PVC - Polyvinyl Chloride outer jacket. For noise protection, it uses an overall Beldfoil® shield with 100% coverage and an 18 AWG (7x26) TC drainwire. UL voltage rating is 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC).
Belden 1471A 010 Key Features
- 24 twisted pairs of 18 AWG (7x26) BC - Bare Copper conductors, plus 1 x 22 AWG (7x30) BC - Bare Copper comm wire.
- PVC - Polyvinyl Chloride insulation with a black PVC - Polyvinyl Chloride outer jacket.
- Overall Beldfoil® shield with 100% coverage and an 18 AWG (7x26) TC drainwire.
- UL voltage rating: 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC).
- Environmental suitability: indoor/outdoor, indoor, outdoor, sunlight resistance, burial.
Belden 1471A 010 Applications
- Supports industrial control and control circuits where multiple signal pairs are routed together through raceways, cable trays, and ducts.
- Works in digital control and low voltage digital control (24v, …) systems where consistent signal routing is needed across equipment and panels.
- Commonly used in distributed control system (DCS) and programmable logic controller (PLC) installations to connect field devices and control I/O.
- Suitable for instruments (4-20ma, 0-10v, ...) to carry instrumentation signals between sensors, transmitters, and control hardware.
- Used with encoders and positioners in automation setups to route control and feedback signals.
- Applied in actuator-driven equipment such as solenoids, valves, and actuators to connect control signals within industrial systems.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor Type | Stranded Conductor |
| Pair insulation thickness (nominal) | 0.017 in (0.43 mm) |
| Pair color code | Black, White and Numbered |
| Comm wire insulation thickness (nominal) | 0.019 in (0.48 mm) |
| Comm Wire color | Orange |
| Outer shield type | Tape |
| Outer shield material | Bi-Laminate (Alum+Poly) |
| Inner shield (comm wire) | No Shield |
| Outer jacket thickness (nominal) | 0.074 in (1.9 mm) |
| Ripcord | Yes |
| Armor | No |
| Overall cable diameter (nominal) | 0.961 in (24.4 mm) |
| Bulk cable weight | 478.8 lbs/1000ft |
| Pair conductor DCR (nominal) | 5.86 Ohm/1000ft (19.2 Ohm/km) |
| Comm wire conductor DCR (nominal) | 14.7 Ohm/1000ft (48.2 Ohm/km) |
| Outer shield DCR (nominal) | 4 Ohm/1000ft (13 Ohm/km) |
| UL temperature | 105°C |
| Operating temperature | -30°C to +105°C |
| Stationary minimum bend radius | 9.6 in (240 mm) |
| Installation minimum bend radius | 9.6 in (240 mm) |
| Max Pull Tension | 1105 lbs (501.2 kg) |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL1685 (FT4 Loading), FT4, 1202 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| UL instrumentation | 24 Pair 18+22AWG (7x26+7x30) Bare Copper, PVC Insulation E1 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, PLTC ITC CMG AWM 2464 SUN RES |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.