Belden 1476A 010, Power Limited Tray Cable 8PR 18 AWG 300V PVC, Black Jacket

SKU:Belden 1476A
● In stock
Description
Belden 1476A 010 is a power-limited tray cable for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It is built with 8 twisted pairs of 18 AWG stranded bare copper conductors plus a 22 AWG communication wire, with PVC insulation and a black PVC outer jacket. For noise rejection in control and signal environments, each pair is individually shielded, and the cable also includes an overall Beldfoil® shield with 100% coverage. UL voltage rating is 300 V (PLTC, CMG, UL AWM 2464), 150 V (ITC).
Belden 1476A 010 Key Features
- 8 twisted pairs of 18 AWG stranded bare copper conductors plus a 22 AWG communication wire.
- PVC insulation with a black PVC outer jacket.
- Individual pair shielding plus an overall Beldfoil® shield with 100% coverage.
- UL voltage rating: 300 V (PLTC, CMG, UL AWM 2464), 150 V (ITC).
- Environmental suitability: indoor/outdoor, indoor, outdoor, sunlight resistance, burial.
Belden 1476A 010 Applications
- Used for industrial control and instrumentation wiring routed through raceways, cable trays, and ducts.
- Supports digital control and control circuits in industrial environments.
- Commonly used in distributed control system (DCS) and programmable logic controller (PLC) installations.
- Suitable for instruments (4-20ma, 0-10v, ...) and low voltage digital control (24v, …) signal connections.
- Connects encoders, solenoids, valves, actuators, and positioners in control and automation systems.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Pairs | 8 |
| Pair Conductor Size | 18 AWG |
| Pair Stranding | 7x26 |
| Pair Conductor Material | BC - Bare Copper |
| Comm Wire(s) | 1 |
| Comm Wire size | 22 AWG |
| Comm Wire stranding | 7x30 |
| Comm Wire material | BC - Bare Copper |
| Conductor Type | Stranded Conductor |
| Insulation thickness (pairs) | 0.017 in (0.43 mm) |
| Pair color code | Black, White and Numbered |
| Insulation thickness (comm wire) | 0.019 in (0.48 mm) |
| Comm wire color code | Orange |
| Individual pair shield | Tape, Bi-Laminate (Alum+Poly), 100% coverage |
| Pair drainwire type | 20 AWG (7x28) TC |
| Overall shield | Tape, Bi-Laminate (Alum+Poly), 100% coverage |
| Overall drainwire type | 18 AWG (7x26) TC |
| Jacket Thickness | 0.063 in (1.6 mm) |
| Overall cable diameter (nominal) | 0.640 in (16.3 mm) |
| Ripcord | Yes |
| Armor | No |
| Nom. Conductor DCR (pairs) | 5.86 Ohm/1000ft (19.2 Ohm/km) |
| Max. Current (pair(s)) | 2.5 Amps per Conductor @ 25°C |
| Nom. conductor DCR (comm wire) | 14.7 Ohm/1000ft (48.2 Ohm/km) |
| Nom. outer shield DCR | 4.47 Ohm/1000ft (14.7 Ohm/km) |
| UL temperature | 105°C |
| Operating temperature | -30°C to +105°C |
| Bend radius (stationary min.) | 6.4 in (160 mm) |
| Bend radius (installation min.) | 6.4 in (160 mm) |
| Max Pull Tension | 501 lbs (227 kg) |
| Bulk cable weight | 236 lbs/1000ft |
| Flammability / reaction to fire | UL1685 (FT4 Loading), FT4, T-29-520, 1202 |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Manufacturer designations | UL Instrumentation, 8 Pair 18+22AWG (7x26+7x30) Bare Copper, PVC Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, Black PVC Outer Jacket, PLTC ITC CMG AWM 2464 SUN RES |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.