Belden 1480A 010, Power Limited Tray Cable 24PR 18 AWG 300V PVC, Black Jacket

SKU:Belden 1480A
● In stock
Description
Belden 1480A 010 is a power limited tray cable for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It is built with 24 twisted pairs of 18 AWG (7x26) BC - Bare Copper conductors with PVC - Polyvinyl Chloride insulation, plus both individual and overall shields. The black PVC - Polyvinyl Chloride outer jacket includes a ripcord for easier installation and is listed for indoor/outdoor use, including sunlight resistance and burial. UL Voltage Rating is 300 V (PLTC, CMG, AWM 2464), 150 V (ITC).
Belden 1480A 010 Key Features
- Power limited tray cable designed for industrial control and instrumentation wiring in raceways, cable trays, and ducts.
- 24 twisted pairs of 18 AWG (7x26) BC - Bare Copper conductors with PVC - Polyvinyl Chloride insulation.
- Both individual and overall shields using Tape, Bi-Laminate (Alum+Poly), 100%.
- Black PVC - Polyvinyl Chloride outer jacket with ripcord.
- Environmental suitability: indoor/outdoor, indoor, outdoor, sunlight resistance, burial.
- UL Voltage Rating: 300 V (PLTC, CMG, AWM 2464), 150 V (ITC).
Belden 1480A 010 Applications
- Designed for industrial control and instrumentation wiring where signals and control must be routed through raceways, cable trays, and ducts.
- Supports distributed control system (DCS) and programmable logic controller (PLC) installations in industrial control environments.
- Commonly used with instruments (4-20ma, 0-10v, ...) and low voltage digital control (24v, …) circuits.
- Suitable for digital control and encoder connections where shielded pair construction is required.
- Used in control circuits for solenoids, valves, actuators, and positioners.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Pairs | 24 |
| Pair Conductor Size | 18 AWG |
| Pair Stranding | 7x26 |
| Pair Conductor Material | BC - Bare Copper |
| Comm Wire(s) | 1 |
| Comm Wire size | 22 AWG |
| Comm Wire stranding | 7x30 |
| Comm Wire material | BC - Bare Copper |
| Conductor Type | Stranded Conductor |
| Pair insulation material | PVC - Polyvinyl Chloride |
| Pair nominal insulation thickness | 0.017 in (0.43 mm) |
| Pair nominal Insulation Diameter | 0.080 in (2.0 mm) |
| Pair color code | ICEA Chart E1 |
| Comm wire insulation material | PVC - Polyvinyl Chloride |
| Comm wire nominal insulation thickness | 0.019 in (0.48 mm) |
| Comm wire nominal insulation diameter | 0.066 in (1.7 mm) |
| Comm Wire color | Orange |
| Shielding configuration | Both individual and overall shields |
| Inner shield (pair(s)) | Tape, Bi-Laminate (Alum+Poly), 100% |
| Inner shield drainwire (pairs) | 20 AWG (7x28) TC |
| Outer shield | Tape, Bi-Laminate (Alum+Poly), 100% |
| Outer shield drainwire | 18 AWG (7x26) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Nominal jacket thickness | 0.074 in (1.9 mm) |
| Nominal cable diameter | 1.061 in (26.95 mm) |
| Ripcord | Yes |
| Armor | No |
| Pair(s) nominal conductor DCR | 6.66 Ohm/1000ft |
| Pairs nominal inner shield DCR | 8.48 Ohm/1000ft (27.8 Ohm/km) |
| Nom. outer shield DCR | 3.8 Ohm/1000ft (12 Ohm/km) |
| Pair(s) nominal capacitance cond-to-cond | 51 pF/ft (170 pF/m) |
| Pair(s) nominal capacitance cond-to-other (conds + Shield) | 95 pF/ft (310 pF/m) |
| Pair(s) nominal inductance | 0.19 µH/ft (0.62 µH/m) |
| Pair(s) max. current | 5 Amps per Conductor @ 30°C |
| Comm wire(s) nominal conductor DCR | 17.2 Ohm/1000ft (56.4 Ohm/km) |
| Comm wire(s) max. current | 9.6 Amps per Conductor @ 30°C |
| UL temperature | 105°C |
| Operating temperature | -30°C to +105°C |
| Bend radius (stationary min.) | 12.7 in (323 mm) |
| Bend radius (installation min.) | 12.7 in (323 mm) |
| Max Pull Tension | 1119 lbs (507.6 kg) |
| Bulk cable weight | 520 lbs/1000ft |
| Thermocouple | No |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |