Belden 1484A 010, Power Limited Tray Cable 4PR 16 AWG 300V PVC, Black Jacket

SKU:Belden 1484A
● In stock
Description
Belden 1484A 010 is a UL instrumentation power limited tray cable designed for industrial control and instrumentation circuits in raceways, cable trays, and ducts. It features 4 twisted pairs of 16 AWG (7x24) BC - Bare Copper conductors plus 1 22 AWG (7x30) BC - Bare Copper comm wire, with PVC - Polyvinyl Chloride insulation and a black PVC - Polyvinyl Chloride jacket. For noise protection, it uses an overall Beldfoil® tape shield with 100% coverage and a 16 AWG (7x24) TC drainwire. Rated 300 V (PLTC, CMG, UL AWM 2464), 150 V (ITC) and -30°C to +105°C, it is suitable for indoor/outdoor use including sunlight resistance and burial.
Belden 1484A 010 Key Features
- Includes 4 twisted pairs of 16 AWG (7x24) BC - Bare Copper conductors plus 1 22 AWG (7x30) BC - Bare Copper comm wire.
- Uses PVC - Polyvinyl Chloride insulation with a black PVC - Polyvinyl Chloride outer jacket.
- Features an overall Beldfoil® tape shield with 100% coverage and a 16 AWG (7x24) TC drainwire.
- UL voltage rating is 300 V (PLTC, CMG, UL AWM 2464) and 150 V (ITC).
- Operating temperature is -30°C to +105°C; UL temperature is 105°C.
- Environmental suitability includes indoor/outdoor, sunlight resistance, and burial.
Belden 1484A 010 Applications
- Supports industrial control and instrumentation circuits where consistent signal and control wiring is required.
- Installs in raceways, cable trays, and ducts to help organize and route control and instrumentation wiring.
- Fits digital control and low voltage digital control (24v, …) connections in control systems.
- Connects instruments (4-20ma, 0-10v, ...) used for monitoring and process measurement.
- Commonly pairs with encoders in control and feedback setups.
- Works in control circuits within distributed control system (DCS) architectures.
- Integrates with programmable logic controller (PLC) wiring for automation and control panels.
- Links field devices such as Solenoids, Valves, Actuators, and Positioners in industrial systems.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor Type | Stranded Conductor |
| Pairs | 4 |
| Comm Wire(s) | 1 |
| Pair insulation thickness (nominal) | 0.017 in (0.43 mm) |
| Pair color code | Black, White and Numbered |
| Comm wire insulation thickness (nominal) | 0.019 in (0.48 mm) |
| Comm Wire color | Orange |
| Outer shield type | Tape |
| Outer shield material | Bi-Laminate (Alum+Poly) |
| Shield Type | Overall aluminum mylar Foil Shield |
| Inner shield (comm wire(s)) | No Shield |
| Jacket thickness (nominal) | 0.053 in (1.3 mm) |
| Ripcord | Yes |
| Armor | No |
| Thermocouple | No |
| Nom. Conductor DCR (pairs) | 3.67 Ohm/1000ft (12.0 Ohm/km) |
| Nom. conductor DCR (comm wire(s)) | 14.7 Ohm/1000ft (48.2 Ohm/km) |
| Nom. outer shield DCR | 3.2 Ohm/1000ft (10 Ohm/km) |
| Overall cable diameter (nominal) | 0.527 in (13.4 mm) |
| Bulk cable weight | 146 lbs/1000ft |
| Bend radius (stationary min.) | 5.3 in (130 mm) |
| Bend radius (installation min.) | 5.3 in (130 mm) |
| Max Pull Tension | 330 lbs (150 kg) |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL1685 (FT4 Loading), FT4, 1202 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Instrumentation Cable |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.