Belden 1492A 010, Power Limited Tray Cable 2 Pair 16 AWG 300V PVC, Black Jacket

SKU:Belden 1492A
● In stock
Description
Belden 1492A 010 is a power limited tray cable for industrial control and instrumentation wiring in raceways, cable trays, and ducts. It is built with 2 pair 16 AWG (7x24) bare copper conductors plus 1 22 AWG (7x30) bare copper comm wire, with PVC insulation and a black PVC outer jacket. For noise-sensitive circuits, it uses individual & overall Beldfoil® shield with 100% coverage. It is rated 300 V (PLTC, CMG, AWM 2464), 150 V (ITC) and is SUN RES for indoor/outdoor use.
Belden 1492A 010 Key Features
- Power limited tray cable for industrial control and instrumentation wiring in raceways, cable trays, and ducts.
- 2 pair 16 AWG (7x24) bare copper conductors plus 1 22 AWG (7x30) bare copper comm wire.
- PVC insulation with a black PVC outer jacket.
- Individual & overall Beldfoil® shield with 100% coverage for noise-sensitive circuits.
- Voltage rating: 300 V (PLTC, CMG, AWM 2464), 150 V (ITC).
- SUN RES for indoor/outdoor use.
Belden 1492A 010 Applications
- Use it for industrial control and control circuits where power limited tray cable is specified.
- Install it in raceways, cable trays, and ducts.
- Support digital control and low voltage digital control (24v, …) signal wiring.
- Connect instruments (4-20ma, 0-10v, ...) and other instrumentation connections.
- Use it in distributed control system (DCS) and programmable logic controller (PLC) wiring.
- Connect field devices such as solenoids, valves, actuators, and positioners.
- Use it with encoders in control and instrumentation systems.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Pairs | 2 |
| Comm Wire(s) | 1 |
| Conductor Type | Stranded conductor |
| Pair Conductor Size | 16 AWG |
| Pair Stranding | 7x24 |
| Pair Conductor Material | BC - Bare Copper |
| Comm Wire size | 22 AWG |
| Comm Wire stranding | 7x30 |
| Comm Wire material | BC - Bare Copper |
| Pair insulation material | PVC - Polyvinyl Chloride |
| Pair nominal insulation thickness | 0.019 in (0.48 mm) |
| Pair nominal Insulation Diameter | 0.095 in (2.4 mm) |
| Pair color code | ICEA Chart E1 |
| Comm wire insulation material | PVC - Polyvinyl Chloride |
| Comm wire nominal insulation thickness | 0.019 in (0.48 mm) |
| Comm wire nominal insulation diameter | 0.066 in (1.7 mm) |
| Comm Wire color | Orange |
| Inner shield (each pair) | Tape, Bi-Laminate (Alum+Poly), 100% |
| Inner shield drainwire | 18 AWG (7x26) TC |
| Outer shield | Tape, Bi-Laminate (Alum+Poly), 100% |
| Outer shield drainwire | 16 AWG (7x24) TC |
| Nominal jacket thickness | 0.053 in (1.3 mm) |
| Overall cable diameter (nominal) | 0.476 in (12.1 mm) |
| Ripcord | Yes |
| Armor | No |
| Pair nominal Conductor DCR | 4.2 Ohm/1000ft |
| Pair nominal inner Shield DCR | 5.58 Ohm/1000ft (18.3 Ohm/km) |
| Nom. outer shield DCR | 3.3 Ohm/1000ft (11 Ohm/km) |
| Pair nominal capacitance Cond-to-Cond | 60 pF/ft (200 pF/m) |
| Pair nominal capacitance Cond-to-other (Conds + Shield) | 110 pF/ft (360 pF/m) |
| Max. Current (pair(s)) | 14 Amps per Conductor @ 30°C |
| Comm Wire nominal Conductor DCR | 17.2 Ohm/1000ft (56.4 Ohm/km) |
| Max. current (comm wire) | 9.6 Amps per Conductor @ 30°C |
| Operating temperature | -30°C to +105°C |
| UL temperature | 105°C |
| Bend radius (stationary min.) | 5.7 in (140 mm) |
| Bend radius (installation min.) | 5.7 in (140 mm) |
| Max Pull Tension | 210 lbs (95 kg) |
| Bulk cable weight | 115 lbs/1000ft |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4 |
| Ratings & Markings | PLTC ITC CMG AWM 2464 SUN RES |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| UL instrumentation | UL instrumentation |
| Priced Per | FT |
| Item Type | Belden Instrumentation Cable |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.