Belden 1502P 877, Multi Conductor Multimedia Control Composite Cable PVC Natural

SKU:Belden 1502P 877
● In stock
Description
Belden 1502P 877 is a plenum-rated multimedia control composite cable that combines a shielded 1 pair 22 AWG stranded (7x30) tinned copper data section with 2 conductor 18 AWG stranded (19x30) tinned copper power conductors. It features foam FEP insulation on the data pair, PVC insulation on the power conductors, and a PVC jacket with a 0.205 in (5.21 mm) nominal overall diameter. The data pair includes a Bi-Laminate (Alum+Poly) tape shield with 100% coverage and a 24 AWG (7x32) TC drainwire. It is UL voltage rated 300 V and listed for indoor plenum installations.
Belden 1502P 877 Key Features
- Composite construction combines 2 conductor(s) + 1 pair(s) to carry both power and data in a single run.
- Data section: 1 pair(s), 22 AWG, stranded (7x30), TC - Tinned Copper with foam FEP insulation (Blue & White).
- Power section: 2 conductor(s), 18 AWG, stranded (19x30), TC - Tinned Copper with PVC insulation (Red & Black).
- Shielded data pair uses a Bi-Laminate (Alum+Poly) tape inner shield with 100% coverage plus a 24 AWG (7x32) TC drainwire.
- PVC - Polyvinyl Chloride jacket in Natural with 0.205 in (5.21 mm) nominal overall diameter.
- Rated UL Voltage Rating: 300 V and listed for indoor - plenum, indoor environments.
Belden 1502P 877 Applications
- Use it for multi-media and lighting automation/control where both data and power are needed in one cable run.
- Support AMX™ and Crestron ® control systems in automation/control installations.
- Install it in indoor plenum environments.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Data pair insulation thickness (nominal) | 0.023 in (0.58 mm) |
| Data pair insulation diameter (nominal) | 0.074 in (1.9 mm) |
| Power conductor insulation thickness (nominal) | 0.011 in (0.28 mm) |
| Power conductor insulation diameter (nominal) | 0.068 in (1.7 mm) |
| Outer shield | No Shield |
| Jacket thickness (nominal) | 0.015 in (0.38 mm) |
| Jacket diameter (nominal) | 0.205 in (5.21 mm) |
| Bulk cable weight | 31 lbs/1000ft |
| Data pair nominal conductor DCR | 18.2 Ohm/1000ft |
| Data pair nominal inner shield DCR | 17.42 Ohm/1000ft (57.15 Ohm/km) |
| Data pair nominal capacitance (Cond-to-Cond) | 14 pF/ft (46 pF/m) |
| Data pair nominal capacitance cond-to-other (Conds + Shield) | 38 pF/ft (120 pF/m) |
| Data pair nominal characteristic impedence | 100 Ohm |
| Data pair nominal inductance | 0.232 µH/ft (0.761 µH/m) |
| Data pair max. current | 6 Amps per Conductor @ 30°C |
| Power Conductors nominal conductor DCR | 6.9 Ohm/1000ft (23 Ohm/km) |
| Power Conductors nominal capacitance cond-to-cond | 29 pF/ft (95 pF/m) |
| Power Conductors nominal inductance | 0.168 µH/ft (0.551 µH/m) |
| Power Conductors max. current | 14 Amps per Conductor @ 30°C |
| UL temperature | 60°C |
| Operating temperature | -20°C to +60°C |
| Bend radius (stationary min.) | 2.1 in (53 mm) |
| Bend radius (installation min.) | 2.1 in (53 mm) |
| Max Pull Tension | 73.1 lbs (33.2 kg) |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| Flammability / reaction to fire | NFPA 262 (UL 910), FT6, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 1502R |
| Item Type | Belden Multi-Pair Cable |
| Priced Per | FT |