Contact1-800-975-3686
Ramcorp Wire & Cable

Belden 1505F Z4B, Coax RG 59 U Type 21 AWG PVC VIO

Belden 1505F Z4B, Coax RG 59 U Type 21 AWG PVC VIO

SKU:Belden 1505F Z4B

Request a Quote

Request a Quote

Description

Specifications

Belden 1505F Z4B, Coax RG 59 U Type 21 AWG PVC VIO specifications
AttributeValue
Conductor nominal diameter0.032 in
Nom. insulation diameter0.145 in (3.68 mm)
Insulation color codeWhite
Overall cable diameter (nominal)0.242 in (6.15 mm)
Bulk cable weight42 lbs/1000ft (63 kg/km)
Nom. conductor DCR12.2 Ohm/1000ft
Nom. outer shield DCR2.4 Ohm/1000ft (7.9 Ohm/km)
Nom. capacitance (Cond-to-Shield)17.0 pF/ft (55.8 pF/m)
Attenuation (nominal) 1 MHz0.2 dB/100ft
Attenuation (Nominal) 3.58 MHz0.5 dB/100ft
Attenuation (Nominal) 5 MHz0.6 dB/100ft
Attenuation (Nominal) 6 MHz0.67 dB/100ft
Attenuation (Nominal) 7 MHz0.73 dB/100ft
Attenuation (nominal) 10 MHz0.9 dB/100ft
Attenuation (Nominal) 12 MHz0.98 dB/100ft
Attenuation (Nominal) 25 MHz1.44 dB/100ft
Attenuation (Nominal) 55 MHz2.2 dB/100ft
Attenuation (Nominal) 67.5 MHz2.4 dB/100ft
Attenuation (Nominal) 71.5 MHz2.5 dB/100ft
Attenuation (Nominal) 88.5 MHz2.8 dB/100ft
Attenuation (nominal) 100 MHz3 dB/100ft
Attenuation (Nominal) 135 MHz3.5 dB/100ft
Attenuation (Nominal) 143 MHz3.6 dB/100ft
Attenuation (Nominal) 180 MHz4.1 dB/100ft
Attenuation (Nominal) 270 MHz5.1 dB/100ft
Attenuation (Nominal) 360 MHz6 dB/100ft
Attenuation (Nominal) 540 MHz7.5 dB/100ft
Attenuation (Nominal) 720 MHz8.9 dB/100ft
Attenuation (Nominal) 750 MHz9.1 dB/100ft
Attenuation (nominal) 1000 MHz10.8 dB/100ft
Attenuation (Nominal) 1500 MHz13.6 dB/100ft
Attenuation (Nominal) 2000 MHz16.1 dB/100ft
Attenuation (Nominal) 2250 MHz17.3 dB/100ft
Attenuation (Nominal) @ 3000 MHz20.7 dB/100ft
Attenuation (Nominal) 4500 MHz26.7 dB/100ft
Attenuation (Nominal) 6000 MHz32.2 dB/100ft
UL temperature60°C
Operating temperature-35°C to +75°C
Installation min. bend radius2.4 in (61 mm)
Max Pull Tension73 lbs (33 kg)
Environmental suitabilityIndoor (Not Riser or Plenum), Indoor
Flammability / reaction to fireUL1685 UL Loading
CPR complianceCPR Euroclass: Eca; CPR UKCA Class: Eca
SustainabilityCA Prop 65
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
Item TypeBelden Coaxial Cable RG59
Priced PerFT

Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.

Need a cut length, bulk pricing, or a spec sheet?

Our team quotes custom lengths and volume orders, usually same day.