Belden 1526A 010 is a power limited tray cable designed for industrial instrumentation and control wiring where reliable signal integrity is critical. It is built with 1 triad of 20 AWG (7x28) BC - Bare Copper conductors with PVC - Polyvinyl Chloride insulation and an overall Beldfoil® shield. The black PVC - Polyvinyl Chloride outer jacket includes a ripcord and is rated for indoor, outdoor, sunlight resistance. Electrical ratings include 300 V (PLTC) and a UL temperature of 105°C.
Belden 1526A 010 Key Features
- Power limited tray cable construction for industrial instrumentation and control wiring.
- 1 triad of 20 AWG (7x28) BC - Bare Copper conductors with PVC - Polyvinyl Chloride insulation.
- Overall Beldfoil® shield (tape) with Bi-Laminate (Alum+Poly) and 100% coverage.
- Black PVC - Polyvinyl Chloride outer jacket with ripcord.
- Environmental suitability: indoor, outdoor, sunlight resistance.
- UL voltage rating: 300 V (PLTC).
- UL temperature: 105°C.
Belden 1526A 010 Applications
- Commonly installed in industrial control systems where dependable control wiring is required.
- Suitable for routing through raceways, cable trays, and ducts in industrial environments.
- Supports digital control and low voltage digital control (24v, …) circuits in control installations.
- Used for instruments (4-20ma, 0-10v, ...) and other signal connections in instrumentation wiring.
- Works with encoders and other control circuits where consistent signal performance is important.
- Applied in distributed control system (DCS) and programmable logic controller (PLC) installations.
- Often connected to devices such as solenoids, valves, actuators, and positioners in control systems.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor configuration | 1 Triad |
| Conductor size | 20 AWG |
| Stranding | 7x28 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. thickness (insulation) | 0.0175 in (0.445 mm) |
| Nom. insulation diameter | 0.071 in (1.8 mm) |
| Color Code | Red, White, Black |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 22 AWG (7x30) TC |
| Ripcord | Yes |
| Armor | No |
| Nom. thickness (jacket) | 0.037 in (0.94 mm) |
| Nom. diameter | 0.231 in |
| Jacket Color | Black |
| Bulk cable weight | 32 lbs/1000ft |
| Nom. conductor DCR | 10.92 Ohm/1000ft |
| Nom. outer shield DCR | 2.09 Ohm/1000ft (6.86 Ohm/km) |
| Nom. capacitance cond-to-cond | 30 pF/ft (98 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 55 pF/ft (180 pF/m) |
| Nom. inductance | 0.19 µH/ft (0.62 µH/m) |
| Max. current | 4.8 Amps per Conductor at 25ºC |
| Operating temperature | -30°C To +105°C |
| Max Pull Tension | 46.9 lbs (21.3 kg) |
| Flammability / reaction to fire | UL 1685 FT4 loading, FT4, T-29-520, IEEE 1202 FT4 |
| NEC / UL compliance | Article 725, Article 727, Article 800 |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Factory markings | PLTC ITC CMG AWM 2464 SUN RES DIR BUR |
| Priced Per | FT |