Belden 1618A 010, Coax CATV Cable 14 AWG LDPE Black

SKU:Belden 1618A 010
● In stock
Description
Belden 1618A 010 is a Series 11 coax CATV cable with 75 Ohm impedance for outdoor environments with water exposure. It features a 14 AWG solid 0.064 in BCCS - Bare Copper Covered Steel center conductor and gas-injected PE - Polyethylene (Foam) insulation. Shielding is Duobond® IV Quad Shield (Foil + 60% Braid + Foil + 40% Braid) with CoreGuard®, and the cable is finished with a PE - Polyethylene jacket with a 0.407 in nominal diameter. Suitability includes indoor, outdoor, and burial, and Plenum (Y/N) is No.
Key Features
- Series 11 coax CATV cable with 75 Ohm nominal characteristic impedance.
- 14 AWG solid 0.064 in BCCS - Bare Copper Covered Steel center conductor.
- Gas-injected PE - Polyethylene (Foam) insulation with 0.28 in nominal diameter.
- Duobond® IV Quad Shield (Foil + 60% Braid + Foil + 40% Braid) with CoreGuard®.
- PE - Polyethylene jacket with 0.407 in nominal diameter.
- Environmental space: Outdoor - Water Exposure.
- Suitability - Indoor: Yes; Suitability - Outdoor: Yes; Suitability - Burial: Yes.
Applications
- Supports CATV coax installations requiring 75 Ohm signal performance.
- Performs in outdoor environments with water exposure.
- Works for indoor, outdoor, and burial installations where these placement options are needed.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| RG type | 11 |
| Series type | 11 |
| Number of coax | 1 |
| Number of Conductors | 1 |
| Shield layers | Layer 1: Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100%; Layer 2: Braid, Aluminum, 60%; Layer 3: Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100%; Layer 4: Braid, Aluminum, 40% |
| Non-UL voltage rating | 300 V RMS |
| Nominal capacitance (conductor-to-shield) | 16.2 pF/ft |
| Nominal inductance | 0.097 μH/ft |
| Nominal delay | 1.2 ns/ft |
| Nominal velocity of propagation (VP) [%] | 83% |
| Return loss | 5 - 1000 MHz, 20 dB (Min. Structural Return Loss (SRL)) |
| Nominal conductor DCR | 11 Ohm/1000ft |
| Nominal outer shield DCR | 3 Ohm/1000ft |
| Outer conductor DCR | 3 Ohm/1000ft |
| High Frequency Attenuation (Max. Insertion Loss) | 5 MHz: 0.38 dB/100ft; 55 MHz: 0.96 dB/100ft; 211 MHz: 1.9 dB/100ft; 270 MHz: 2.13 dB/100ft; 300 MHz: 2.25 dB/100ft; 350 MHz: 2.42 dB/100ft; 400 MHz: 2.6 dB/100ft; 450 MHz: 2.75 dB/100ft; 550 MHz: 3.04 dB/100ft; 750 MHz: 3.65 dB/100ft; 870 MHz: 4.06 dB/100ft; 1000 MHz: 4.35 dB/100ft |
| Bulk cable weight | 52 lbs/1000ft |
| Maximum recommended pulling tension | 308 lbs |
| Minimum minor axis bend radius | 4.25 in |
| Operating Temperature Range | -55°C To +80°C |
| Plenum (Y/N) | No |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/96/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU directive compliance | EU Directive 2003/11/EC (BFR) |
| EU CE mark | No |
| MII Order #39 (China RoHS) | Yes |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.