Belden 1694D 010, Coax Dual RG 6 2C 18 AWG PE SH PVC Black

Description
Belden 1694D 010 is a low loss serial digital coax in a dual RG 6 format for video distribution and other broadband 75 Ohm applications. It features 2-RG6 18 AWG solid bare copper conductors and PE - Polyethylene (Foam) insulation with Gas Injected construction. Shielding combines Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100% with a Tinned Copper (TC), 95% braid. The cable is finished with PVC - Polyvinyl Chloride inner jackets and an overall PVC - Polyvinyl Chloride jacket in Black, and it is rated CMR with a UL Voltage Rating of 300 V RMS.
Belden 1694D 010 Key Features
- Dual coax design in an RG 6 Dual format with Number of coax: 2.
- 18 AWG solid conductor using BC - Bare Copper for the center conductor.
- PE - Polyethylene (Foam) insulation with Gas Injected construction.
- Shield Type: Both, braid over foil, combining Duofoil®, 100% with a Tinned Copper (TC), 95% braid.
- PVC - Polyvinyl Chloride inner jackets and PVC - Polyvinyl Chloride outer jacket with Jacket Color: Black.
- Nominal characteristic impedance: 75 Ohm and UL Voltage Rating: 300 V RMS.
- NEC/(UL) compliance: CMR with UL flammability: UL1666 Vertical Shaft.
Belden 1694D 010 Applications
- Use it for Video Mult. applications.
- Choose it for video distribution and other broadband 75 Ohm applications.
- Install it in riser applications where CMR requirements apply.
- Specify it for Indoor/Outdoor environments, with Suitability - indoor: Yes and Suitability - outdoor: Yes.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Coax construction | Dual |
| Coax Type | RG 6 Dual |
| RG type | 6 |
| Series type | 6 |
| Nominal Conductor Diameter | 0.04 in |
| Nominal conductor DCR | 6.4 Ohm/1000ft |
| Insulation nominal diameter | 0.18 in |
| Tape (Layer 1) | Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100% |
| Braid (Layer 2) | Tinned Copper (TC), 95% |
| Nominal inner Shield DCR | 2.8 Ohm/1000ft |
| Outer conductor DCR | 2.8 Ohm/1000ft |
| Flooded | No not flooded over braid |
| Inner Jacket Nominal Diameter | 0.275 in |
| Outer jacket nominal diameter | 0.618 in |
| Nom. capacitance (Conductor to Shield) | 16.2 pF/ft |
| Nominal delay | 1.24 ns/ft |
| Nominal velocity of propagation (VP) [%] | 82% |
| Return loss (5 - 1600 MHz) | 23 dB |
| Return loss (1600 - 4500 MHz) | 21 dB |
| Insertion loss @ 1 MHz | 0.24 dB/100ft |
| Insertion Loss (3.58 MHz) | 0.44 dB/100ft |
| Insertion loss 5 MHz | 0.52 dB/100ft |
| Insertion Loss (7 MHz) | 0.61 dB/100ft |
| Insertion loss @ 10 MHz | 0.71 dB/100ft |
| Insertion Loss (67.5 MHz) | 1.65 dB/100ft |
| Insertion Loss (71.5 MHz) | 1.69 dB/100ft |
| Insertion Loss (88.5 MHz) | 1.86 dB/100ft |
| Insertion loss @ 100 MHz | 1.95 dB/100ft |
| Insertion Loss (135 MHz) | 2.24 dB/100ft |
| Insertion Loss (143 MHz) | 2.3 dB/100ft |
| Insertion Loss (180 MHz) | 2.57 dB/100ft |
| Insertion Loss (270 MHz) | 3.17 dB/100ft |
| Insertion Loss (360 MHz) | 3.69 dB/100ft |
| Insertion Loss (540 MHz) | 4.6 dB/100ft |
| Insertion Loss (720 MHz) | 5.38 dB/100ft |
| Insertion Loss (750 MHz) | 5.5 dB/100ft |
| Insertion loss @ 1000 MHz | 6.42 dB/100ft |
| Insertion loss 1500 MHz | 7.99 dB/100ft |
| Insertion Loss (2000 MHz) | 9.37 dB/100ft |
| Insertion Loss (2250 MHz) | 10.01 dB/100ft |
| Insertion Loss (3000 MHz) | 11.78 dB/100ft |
| Insertion Loss (4500 MHz) | 15.7 dB/100ft |
| Operating Temperature Range | -40°C To +75°C |
| Non-UL temp rating | 75°C |
| UL Temperature Rating | 60°C |
| Bulk cable weight | 124 lbs/1000ft |
| Maximum recommended pulling tension | 177 lbs |
| Minimum minor axis bend radius | 3.5 in |
| CEC / C(UL) compliance | CMG |
| CPR Euroclass | Eca |
| Plenum (Y/N) | No |
| Environmental space | Indoor/Outdoor |
| Suitability - indoor | Yes |
| Suitability - Outdoor | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU directive compliance | EU Directive 2003/11/EC (BFR) |
| EU CE mark | No |
| MII Order #39 (China RoHS) | Yes |
| Color chart | 1: Red; 2: Green |
| Item Type | Belden Coaxial Cable RG6 |
| Other Part Numbers | 1694D 010, 1694D 010100, 1694D 010250, 1694D 010500, 1694D 0101000 |
| Priced Per | FT |