Belden 1694F G7V, QLTHLDFHDLDPE DBLB FRPVC Red Matte

Description
Belden 1694F G7V is a 75 Ohm SDI coax based on an RG-6 design for high-performance digital video transmission, including 6 Gb/s UHDTV and HD-SDI 1080p. It features a 19 AWG (7x27) BC - Bare Copper stranded conductor with PE - Polyethylene (Foam) insulation and a PVC - Polyvinyl Chloride jacket. The cable includes a double 95% Tinned Copper (TC) braid shield and is rated CM for indoor (not riser or plenum) installations. Electrical performance includes 80% nominal velocity of propagation and return loss performance up to 6000 MHz.
Belden 1694F G7V Key Features
- RG-6 coax design with 75 Ohm nominal characteristic impedance for SDI digital video transmission.
- 19 AWG (7x27) BC - Bare Copper stranded conductor with PE - Polyethylene (Foam) insulation.
- Double braid shielding: layer 1 Tinned Copper (TC) 95% and layer 2 Tinned Copper (TC) 95%.
- PVC - Polyvinyl Chloride jacket with CM rating for indoor (not riser or plenum) use.
- Return loss performance specified up to 6000 MHz, with 80% nominal velocity of propagation.
Belden 1694F G7V Applications
- Use it for digital video signal transmission where consistent performance is required.
- Support 6 Gb/s UHDTV video distribution in professional video signal paths.
- Deploy it for HD-SDI 1080p connections in video systems and infrastructure.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Overall cable diameter (nominal) | 0.276 in (7.01 mm) |
| Conductor nominal diameter | 0.041 in |
| Insulation diameter (nominal) | 0.180 in (4.57 mm) |
| Insulation color code | White |
| Jacket diameter (nominal) | 0.276 in (7.01 mm) |
| Bulk cable weight | 50 lbs/1000ft |
| Nom. conductor DCR | 8.5 Ohm/1000ft |
| Nom. outer shield DCR | 1.7 Ohm/1000ft (5.6 Ohm/km) |
| Nom. capacitance (Cond-to-Shield) | 17.0 pF/ft (55.8 pF/m) |
| UL Voltage Rating | 300 V (CM) |
| Return loss | 5 - 850 MHz: 20 dB; 850 - 6000 MHz: 15 dB |
| Attenuation (nom.) | 1 MHz: 0.24 dB/100ft; 3.58 MHz: 0.45 dB/100ft; 5 MHz: 0.54 dB/100ft; 6 MHz: 0.55 dB/100ft; 7 MHz: 0.62 dB/100ft; 10 MHz: 0.72 dB/100ft; 12 MHz: 0.83 dB/100ft; 25 MHz: 1.18 dB/100ft; 55 MHz: 1.76 dB/100ft; 67.5 MHz: 1.9 dB/100ft; 71.5 MHz: 2.0 dB/100ft; 88.5 MHz: 2.2 dB/100ft; 100 MHz: 2.4 dB/100ft; 135 MHz: 2.8 dB/100ft; 143 MHz: 2.9 dB/100ft; 180 MHz: 3.3 dB/100ft; 270 MHz: 4.0 dB/100ft; 360 MHz: 4.7 dB/100ft; 540 MHz: 5.9 dB/100ft; 720 MHz: 6.9 dB/100ft; 750 MHz: 7.1 dB/100ft; 1000 MHz: 6.3 dB/100ft; 1500 MHz: 7.8 dB/100ft; 2000 MHz: 12.5 dB/100ft; 2250 MHz: 13.4 dB/100ft; 3000 MHz: 15.9 dB/100ft; 4500 MHz: 20.6 dB/100ft; 6000 MHz: 28.7 dB/100ft |
| UL temperature | 60°C |
| Operating temperature | -35°C to +75°C |
| Installation min. bend radius | 2.75 in (69.9 mm) |
| Max Pull Tension | 90 lbs (41 kg) |
| Flammability / reaction to fire | UL 1685 - UL Loading |
| NEC / UL compliance | CM |
| CEC / C(UL) compliance | CM |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Coaxial Cable RG6 |
| Other Part Numbers | 1694F G7V, 1694F G7V100, 1694F G7V250, 1694F G7V500, 1694F G7V1000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.