Belden 1694WB 010, Coax Flooded RG 6 U Type 18 AWG PE Black

Description
Belden 1694WB 010 is a low loss serial digital coax for demanding video transport, including SMPTE 424M 3 Gb/s HD-SDI 1080p. It uses an RG6 construction with an 18 AWG solid bare copper conductor, a gas injected foam HDPE core, and a black PE jacket. Shielding features Duofoil® plus a 95% tinned copper braid, and it includes waterblocking grease for outdoor - water exposure environments. UV resistance and suitability for burial and aerial runs (when supported by messenger Wire) support rugged outdoor installations.
Belden 1694WB 010 Key Features
- Low loss serial digital coax for demanding video transport, including SMPTE 424M 3 Gb/s HD-SDI 1080p.
- RG6 coax construction with 1 coax and 1 conductor.
- 18 AWG solid bare copper (BC - Bare Copper) conductor with 0.04 in nominal diameter.
- Gas injected PE - Polyethylene (foam) insulation (dielectric) with 0.18 in nominal diameter.
- Shielding includes Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100% plus a 95% tinned copper (TC) braid.
- Outer shield flooding grease and waterblocking grease for outdoor - water exposure environments.
- Black PE - Polyethylene jacket with 0.274 in nominal diameter and UV resistance: Yes.
Belden 1694WB 010 Applications
- Supports SMPTE 424M 3 Gb/s HD-SDI 1080p video transport in demanding installations.
- Works in outdoor - water exposure environments where waterblocking grease is needed.
- Meets burial installation needs where suitability - burial is required.
- Enables aerial runs when supported by messenger Wire.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Nominal characteristic impedance | 75 Ohm |
| Nom. capacitance (Conductor to Shield) | 16.2 pF/ft |
| Nominal inductance | 0.106 µH/ft |
| Nominal delay | 1.24 ns/ft |
| Nominal velocity of propagation (VP) [%] | 82% |
| Nominal conductor DCR | 6.4 Ohm/1000ft |
| Nominal outer shield DCR | 2.8 Ohm/1000ft |
| Return Loss (5 MHz - 1600 MHz) | 23 dB |
| Return Loss (1600 MHz - 4500 MHz) | 21 dB |
| Return Loss notes | Return Loss: Fixed bridge and termination |
| High Frequency insertion loss (1 MHz) | 0.24 dB/100ft |
| High Frequency insertion loss (3.58 MHz) | 0.44 dB/100ft |
| High Frequency insertion loss (5 MHz) | 0.52 dB/100ft |
| High Frequency insertion loss (6 MHz) | 0.57 dB/100ft |
| High Frequency insertion loss (7 MHz) | 0.61 dB/100ft |
| High Frequency insertion loss (10 MHz) | 0.71 dB/100ft |
| High Frequency insertion loss (12 MHz) | 0.78 dB/100ft |
| High Frequency insertion loss (25 MHz) | 1.08 dB/100ft |
| High Frequency insertion loss (67.5 MHz) | 1.65 dB/100ft |
| High Frequency insertion loss (71.5 MHz) | 1.69 dB/100ft |
| High Frequency insertion loss (88.5 MHz) | 1.86 dB/100ft |
| High Frequency insertion loss (100 MHz) | 1.95 dB/100ft |
| High Frequency insertion loss (135 MHz) | 2.24 dB/100ft |
| High Frequency insertion loss (143 MHz) | 2.3 dB/100ft |
| High Frequency insertion loss (180 MHz) | 2.57 dB/100ft |
| High Frequency insertion loss (270 MHz) | 3.17 dB/100ft |
| High Frequency insertion loss (360 MHz) | 3.69 dB/100ft |
| High Frequency insertion loss (540 MHz) | 4.5 dB/100ft |
| High Frequency insertion loss (720 MHz) | 5.3 dB/100ft |
| High Frequency insertion loss (750 MHz) | 5.4 dB/100ft |
| High Frequency insertion loss (1000 MHz) | 6.3 dB/100ft |
| High Frequency insertion loss (1500 MHz) | 7.8 dB/100ft |
| High Frequency insertion loss (2000 MHz) | 9.2 dB/100ft |
| High Frequency insertion loss (2250 MHz) | 9.8 dB/100ft |
| High Frequency insertion loss (3000 MHz) | 11.5 dB/100ft |
| High Frequency insertion loss (4500 MHz) | 14.5 dB/100ft |
| Bulk cable weight | 36 lbs/1000ft |
| Maximum recommended pulling tension | 69 lbs |
| Minimum minor axis bend radius | 2.75 in |
| Operating Temperature Range | -55°C To +80°C |
| Environmental space | Outdoor - Water Exposure |
| Suitability - Outdoor | Yes |
| Suitability - burial | Yes |
| Suitability - aerial | Yes - When supported by messenger Wire |
| Suitability - indoor | No |
| Suitability - hazardous locations | No |
| Suitability - sunlight resistance | No |
| Plenum (Y/N) | No |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/96/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU directive compliance | EU Directive 2003/11/EC (BFR) |
| EU CE mark | No |
| MII Order #39 (China RoHS) | Yes |
| Footnote | C - CRATE REEL PUT-UP. |
| Item Type | Belden Coaxial Cable RG6 |
| Other Part Numbers | 1694WB 010, 1694WB 010100, 1694WB 010250, 1694WB 010500, 1694WB 0101000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.