Contact1-800-975-3686
Ramcorp Wire & Cable

Belden 1695A 007, Low Loss Serial Digital Coax 18 AWG FFEP Violet

Belden 1695A 007, Low Loss Serial Digital Coax 18 AWG FFEP Violet

SKU:Belden 1695A 007

$1,334.00

In stock

× 250 ft = Total: 250 ft

Description

Specifications

Belden 1695A 007, Low Loss Serial Digital Coax 18 AWG FFEP Violet specifications
AttributeValue
Overall cable diameter (nominal)0.229 in (5.82 mm)
Conductor diameter (nominal)0.040 in
Insulation MaterialFEP - Fluorinated Ethylene Propylene (Foam)
Insulation diameter (nominal)0.170 in (4.32 mm)
Insulation color codeWhite
Bulk cable weight41 lbs/1000ft
Non-Plenum number1694A
Nom. conductor DCR6.4 Ohm/1000ft
Nom. outer shield DCR2.8 Ohm/1000ft (9.2 Ohm/km)
Nom. capacitance (Cond-to-Shield)16.2 pF/ft (53.1 pF/m)
Nom. velocity of prop.83%
Return loss (5 - 1600 MHz)23 dB
Return loss (1600 - 4500 MHz)21 dB
Return loss (4500 - 6000 MHz)15 dB
Attenuation (Nom.) 1 MHz0.24 dB/100ft
Attenuation (Nom.) 3.58 MHz0.45 dB/100ft
Attenuation (Nom.) 5 MHz0.55 dB/100ft
Attenuation (Nom.) 7 MHz0.65 dB/100ft
Attenuation (Nom.) 10 MHz0.75 dB/100ft
Attenuation (Nom.) 67.5 MHz1.74 dB/100ft
Attenuation (Nom.) 71.5 MHz1.78 dB/100ft
Attenuation (Nom.) 88.5 MHz1.94 dB/100ft
Attenuation (Nom.) 100 MHz2.1 dB/100ft
Attenuation (Nom.) 135 MHz2.4 dB/100ft
Attenuation (Nom.) 143 MHz2.5 dB/100ft
Attenuation (Nom.) 180 MHz2.8 dB/100ft
Attenuation (Nom.) 270 MHz3.4 dB/100ft
Attenuation (Nom.) 360 MHz4.0 dB/100ft
Attenuation (Nom.) 540 MHz5.2 dB/100ft
Attenuation (Nom.) 720 MHz6.1 dB/100ft
Attenuation (Nom.) 750 MHz6.2 dB/100ft
Attenuation (Nom.) 1000 MHz7.4 dB/100ft
Attenuation (Nom.) 1500 MHz9.5 dB/100ft
Attenuation (Nom.) 2000 MHz11.3 dB/100ft
Attenuation (Nom.) 2250 MHz12.2 dB/100ft
Attenuation (Nom.) 3000 MHz14.6 dB/100ft
Attenuation (Nom.) 4500 MHz18.6 dB/100ft
Attenuation (Nom.) 6000 MHz22.4 dB/100ft
UL temperature75°C
Operating0°C to +75°C
Installation min. bend radius2.3 in (58 mm)
Max Pull Tension92 lbs (42 kg)
Environmental suitabilityIndoor - Plenum, Indoor
NEC / UL complianceCMP
CEC / C(UL) complianceCMP
Flammability / reaction to fireNFPA 262
CPR complianceCPR Euroclass: Eca; CPR UKCA Class: Eca
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
SustainabilityCA Prop 65
Priced PerFT

Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.

Need a cut length, bulk pricing, or a spec sheet?

Our team quotes custom lengths and volume orders, usually same day.