Belden 19108 010, Portable Cordage 3C 16 AWG EPDM Rubber Jacket, Black Jacket

SKU:Belden 19108 010
● In stock
Description
Belden 19108 010 is cordage with 3 stranded 16 AWG BC - Bare Copper conductors, EPDM - Ethylene Propylene Diene Monomer insulation, and an SBR - Styrene Butadiene Rubber outer jacket. This unshielded UL Type S portable cordage is rated 600 V and 60°C and is suitable for Indoor, Outdoor installations. It includes a cotton serve separator and uses a Black, White, Green color code with a Black jacket.
Belden 19108 010 Applications
- Use it for portable cordage installations that require flexibility in demanding environments.
- Choose it for power and equipment cord applications where an unshielded construction is appropriate.
- Specify it for Indoor, Outdoor use when a UL Type S cord is required.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Product type | Cordage |
| Number of Conductors | 3 |
| Conductor size | 16 AWG |
| Conductor stranding | 65x34 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | EPDM - Ethylene Propylene Diene Monomer |
| Nom. thickness (insulation) | 0.033 in (0.84 mm) |
| Nom. insulation diameter | 0.123 in mm |
| Color Code | Black, White, Green |
| Outer shield | No Shield |
| Separator | Cotton Serve |
| Outer jacket material | SBR - Styrene Butadiene Rubber |
| Nom. thickness (outer jacket) | 0.065 in (1.7 mm) |
| Overall cable diameter (nominal) | 0.405 in |
| Jacket Color | Black |
| UL Voltage Rating | 600 V |
| Nom. conductor DCR | 4.17 Ohm/1000ft |
| Max. current | 10 Amps per Conductor at 25ºC (over 50 ft) |
| UL temperature | 60°C |
| Operating | -20°C To +60°C |
| Bend radius (stationary min.) | 4.05 in (103 mm) |
| Bend radius (installation min.) | 4.05 in |
| Max Pull Tension | 97.5 lbs (44.2 kg) |
| Bulk cable weight | 90 lbs/1000ft |
| Environmental suitability | Indoor, Outdoor |
| UL type | UL Type S |
| Standards | UL/CSA |
| NEC / UL compliance | Article 400, S |
| Flammability / reaction to fire | FT2 |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
| Other Part Numbers | 19108 010, 19108 010100, 19108 010250, 19108 010500, 19108 0101000, UPC 612825126508 |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.