Belden 28600AS 010, Control Cable 18 AWG 6C Foil Shield PVC NYL 600V, Black Jacket

SKU:Belden 28600AS 010
● In stock
Description
Belden 28600AS 010 is a 18 AWG, 6-conductor VNTC control cable for power and control applications up to 600V. It uses 6 conductor 18AWG (7x26) BC - Bare Copper conductors with PVC-NYL insulation and an overall Beldfoil® shield for noise protection. The cable is finished with a black PVC outer jacket and includes a ripcord to support easier installation. Ratings/markings include 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR, and it is UL Type TC (1277) PVC-Nylon/PVC.
Belden 28600AS 010 Key Features
- This 18 AWG, 6-conductor VNTC control cable is designed for power and control applications up to 600V.
- It features 6 conductor 18AWG (7x26) BC - Bare Copper conductors with stranded construction.
- PVC-NYL insulation uses the PVC-NYL insulation E2 color code with conductor colors: Black, Red, Blue, Orange, Yellow, Brown.
- An overall Beldfoil® shield (tape) uses Bi-Laminate (Alum+Poly) material with 100% coverage.
- The black PVC - Polyvinyl Chloride outer jacket includes a ripcord.
- UL Type TC (1277) PVC-Nylon/PVC; suitable for TC-ER and NPLF applications.
- Ratings/markings: 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR.
Belden 28600AS 010 Applications
- Supports power and control applications up to 600V.
- Works in installation environments described as Indoor, Outdoor, Sunlight Resistance, UV Resistance, Burial.
- Meets applications where the cable is marked 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Nom. insulation thickness | 0.021 in (0.53 mm) |
| Nom. insulation diameter | 0.088 in mm |
| Nom. jacket thickness | 0.047 in (1.2 mm) |
| Overall cable diameter (nominal) | 0.362 in (9.19 mm) |
| Bulk cable weight | 83 lbs/1000ft |
| UL Voltage Rating | 600 V (TC-ER), 150 V (NPLF) |
| Nom. conductor DCR | 6.66 Ohm/1000ft |
| Max. current | 11.2 Amps per Conductor at 30ºC |
| UL temperature | 90°C Dry, 90°C Wet |
| Operating temperature | -30°C To +90°C |
| Flammability / reaction to fire | UL1685 UL Loading, FT4, IEEE 1202 FT4 |
| Bend radius (stationary min.) | 4.344 in (110.3 mm) |
| Bend radius (installation min.) | 4.344 in (110.3 mm) |
| Max Pull Tension | 154 lbs (69.9 kg) |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, UV Resistance, Burial |
| NEC / UL compliance | Article 336, TC-ER, NPLF, TFFN |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Plenum number | ICEA S-73-532, S-61-402 |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.