Belden 29506 010, Flexible Motor Supply Cable 3C 4 AWG PVC Jacket

SKU:Belden 29506 010
● In stock
Description
Belden 29506 010 is a 300% ground flexible VFD cable for Variable Frequency Drives (VFD), AC motor and drive systems, and Class 1 Division 2 hazardous locations. It is built with 3 conductors of 4 AWG TC - Tinned Copper and XLPE - Cross-Linked Polyethylene (Thermoset) insulation (ICEA Chart M4), plus a PVC - Polyvinyl Chloride insulated ground. For noise control and EMI performance, it uses an overall Beldfoil® shield with a Tinned Copper braid, finished with a black PVC - Polyvinyl Chloride jacket. Ratings include 1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC), and UL temperature 90°C Dry, 90°C Wet.
Belden 29506 010 Key Features
- 300% ground flexible VFD cable design for Variable Frequency Drives (VFD), AC motor and drive systems, and Class 1 Division 2 hazardous locations.
- 3 x 4 AWG TC - Tinned Copper conductors with XLPE - Cross-Linked Polyethylene (Thermoset) insulation and ICEA Chart M4 conductor color code.
- Overall shield: Beldfoil® + Tinned Copper braid for noise control and EMI performance.
- Black PVC - Polyvinyl Chloride jacket with environmental suitability: Indoor, Outdoor, Sunlight Resistance, Burial.
- UL voltage rating: 1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC); voltage rating: 1000 V (AWM I/II A/B).
- UL temperature: 90°C Dry, 90°C Wet; operating temperature: -40°C To +90°C.
Belden 29506 010 Applications
- Designed for Variable Frequency Drives (VFD) in motor and drive installations.
- Used in AC motor and drive systems where a flexible VFD cable is required.
- Suitable for Class 1 Division 2 hazardous locations when this cable type is called for.
- Recommended cable gland: Belden BTC125A1271RA.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 4 AWG |
| Conductor stranding | 7x19x25 |
| Conductor Material | TC - Tinned Copper |
| Insulated ground | 1 x 4 AWG, 7x19x25, TC - Tinned Copper, insulated ground wire |
| Uninsulated ground wire | 4 x 10 AWG, 105x30, TC - Tinned Copper, segmented ground wire (4 totaling 4 AWG) |
| Ground wire insulation material | PVC - Polyvinyl Chloride |
| Ground wire color code | Green/Yellow Stripe |
| Tape shield material | Tri-Laminate (Alum+Poly+Alum) |
| Tape shield coverage | 100% |
| Drainwire type | 10 AWG (105x30) TC |
| Braid shield material | Tinned Copper (TC) |
| Braid shield coverage | 86% |
| Ripcord | Yes |
| Conductor insulation nominal thickness | 0.062 in (1.6 mm) |
| Conductor nominal insulation diameter | 0.367 in (9.32 mm) |
| Ground wire nominal thickness | 0.062 in (1.6 mm) |
| Ground wire nominal insulation diameter | 0.367 in (9.32 mm) |
| Outer jacket nominal thickness | 0.093 in (2.4 mm) |
| Overall cable diameter (nominal) | 1.113 in (28.27 mm) |
| Bulk cable weight | 1061 lbs/1000ft |
| Nom. Conductor DCR (Conductor(s)) | 0.239 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 32 pF/ft (100 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 60 pF/m (18 pF/ft) |
| Nom. characteristic impedence | 37 Ohm |
| Nom. inductance cond-grnd | 0.12 µH/ft |
| Nom. velocity of prop. | 55% |
| Max. current | 95 Amps per Conductor at 30ºC |
| Nom. conductor DCR (insulated ground) | 0.2689 Ohm/1000ft (0.8822 Ohm/km) |
| Nom. Conductor DCR (uninsulated ground wire) | 0.2689 Ohm/1000ft (0.8822 Ohm/km) |
| Nom. outer shield DCR | 0.21 Ohm/1000ft (0.69 Ohm/km) |
| Bend radius (stationary min.) | 13.4 in (340 mm) |
| Bend radius (installation min.) | 13.4 in (340 mm) |
| Max Pull Tension | 2420 lbs (1100 kg) |
| NEC / UL compliance | Article 336, TC-ER, WTTC, UL Flexible Motor Supply Cable |
| AWM compliance | AWM I/II A/B |
| CEC / C(UL) compliance | CIC, TC |
| ICEA compliance | S-95-658 |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Other Part Numbers | 29506 010, 29506 010100, 29506 010250, 29506 010500, 29506 0101000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.