Belden 29507 010, Flexible Motor Supply Cable 2 AWG 4C 1000V PVC

SKU:Belden 29507 010
● In stock
Description
Belden 29507 010 is a 300% ground flexible VFD cable for Variable Frequency Drives (VFD), AC motor, and drive systems, including Class 1 Division 2 hazardous locations (recommended cable gland Belden BTC150A1501RA). It is built with 3 conductors of 2 AWG stranded tinned copper and XLPE insulation (ICEA Chart M4), plus an insulated 2 AWG ground and segmented 8 AWG grounds. For noise control, it includes an overall Beldfoil® shield with a tinned copper braid shield, and it is finished with a black PVC outer jacket. Voltage ratings include 1000 V and 600 V (C(UL) CIC TC), with an operating temperature of -40°C to +90°C.
Belden 29507 010 Key Features
- 300% ground flexible VFD cable designed for Variable Frequency Drives (VFD), AC motor, and drive systems, including Class 1 Division 2 hazardous locations (recommended cable gland Belden BTC150A1501RA).
- 3 x 2 AWG stranded tinned copper conductors with XLPE insulation and conductor color code ICEA Chart M4.
- Grounding construction includes 1 x 2 AWG PVC-insulated ground and 4 x 8 AWG segmented ground wires (4 totaling 2 AWG), with earth/ground wires: Yes.
- Shielding system includes an overall Beldfoil® shield (Tri-Laminate (Alum+Poly+Alum), 100% coverage) plus a tinned copper braid shield with 87% coverage.
- Black PVC outer jacket with ripcord: Yes; environmental suitability includes indoor, outdoor, sunlight resistance, burial, and oil resistant.
Belden 29507 010 Applications
- Supports Variable Frequency Drives (VFD) where a flexible VFD cable is specified for drive and motor connections.
- Use it in AC motor and drive systems that require a shielded construction for noise control.
- Specify it for Class 1 Division 2 hazardous locations when paired with the recommended cable gland Belden BTC150A1501RA.
- Install it in indoor and outdoor environments, including sunlight resistance and burial conditions.
- Select it for locations where oil resistant cable is required.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 2 AWG |
| Conductor stranding | 7x19x23 |
| Conductor Material | TC - Tinned Copper |
| Insulated ground | 1 x 2 AWG, 7x19x23, TC - Tinned Copper (insulated ground wire) |
| Segmented ground wire | 4 x 8 AWG, 7x19x29, TC - Tinned Copper (4 totaling 2 AWG) |
| Conductor insulation material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Conductor insulation nominal thickness | 0.062 in (1.6 mm) |
| Conductor nominal insulation diameter | 0.454 in (11.5 mm) |
| Ground wire insulation material | PVC - Polyvinyl Chloride |
| Ground wire insulation nominal thickness | 0.062 in (1.6 mm) |
| Ground wire nominal insulation diameter | 0.454 in (11.5 mm) |
| Ground wire color | Green/Yellow Stripe |
| Shielded | Yes |
| Shield Type | Braid |
| Drainwire type | 8 AWG (7x19x28) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Outer jacket nominal thickness | 0.095 in (2.4 mm) |
| Overall cable diameter (nominal) | 1.324 in (33.63 mm) |
| Armor | No |
| Composite | No |
| TC SUN RES DIR BUR | |
| Nom. conductor DCR | 0.152 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 35 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 66 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 46 Ohm |
| Nom. inductance cond-grnd | 0.098 µH/ft |
| Nom. velocity of prop. | 55% |
| Max. current | 130 Amps per Conductor at 30ºC |
| Insulated ground DCR | 0.147 Ohm/1000ft (0.482 Ohm/km) |
| Nom. outer shield DCR | 0.43 Ohm/1000ft (1.4 Ohm/km) |
| UL Voltage Rating | 1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) |
| Voltage Rating | 1000 V (AWM I/II A/B) |
| Voltage range | 1KV |
| UL temperature | 90°C Dry, 90°C Wet |
| Operating temperature | -40°C To +90°C |
| Bend radius (stationary min.) | 15.9 in (404 mm) |
| Bend radius (installation min.) | 15.9 in (404 mm) |
| Max Pull Tension | 3987 lbs (1808 kg) |
| Bulk cable weight | 1546 lbs/1000ft |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, TC-ER, WTTC, UL Flexible Motor Supply Cable |
| AWM compliance | AWM I/II A/B |
| CEC / C(UL) compliance | CIC, TC |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Other Part Numbers | 29507 010, 29507 010100, 29507 010250, 29507 010500, 29507 0101000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.