Belden 29523C 010, Multi Conductor 3 10 AWG 600V CU TAPE PVC Black

SKU:Belden 29523C 010
● In stock
Description
Belden 29523C 010 is a Belden Basics VFD cable for Variable Frequency Drives (VFD) and AC motor/drive systems, including Class 1 Division 2 hazardous locations. It is built with 3 10 AWG (7x18) BC - Bare Copper conductors, XLPE - Cross-Linked Polyethylene (Thermoset) insulation, and a 10 AWG symmetrical segmented ground (3 of 14 AWG) in continuous contact with an overall dual copper tape helically applied shield. The black PVC - Polyvinyl Chloride jacket includes a ripcord and is marked 1000V SUN RES DIR BUR Oil Resistant. UL Voltage Rating is 600 / 1000 V (TC-ER) with UL temperature 90°C Dry, 90°C Wet.
Belden 29523C 010 Key Features
- Designed for Variable Frequency Drives (VFD) and AC motor/drive systems, including Class 1 Division 2 hazardous locations.
- 3 10 AWG (7x18) BC - Bare Copper conductors with ASTM B3 Copper B8 Class B Stranding.
- 10 AWG symmetrical segmented ground (3 of 14 AWG) with 3 ground segments totaling 10+ AWG.
- XLPE - Cross-Linked Polyethylene (Thermoset) insulation with color code ICEA Chart M4; ground wire insulation: No Insulation.
- Overall dual copper tape helically applied shield with shield type: Helical Tape, shield material: Bare Copper (BC), and shield coverage: 100%.
- Black PVC - Polyvinyl Chloride jacket with ripcord: Yes; jacket ratings/markings: 1000V SUN RES DIR BUR Oil Resistant.
- UL Voltage Rating: 600 / 1000 V (TC-ER) and UL temperature: 90°C Dry, 90°C Wet.
Belden 29523C 010 Applications
- Suitable for Variable Frequency Drives (VFD) where a dedicated VFD cable is specified for drive-to-motor connections.
- Supports AC motor and drive systems in installations identified as Class 1 Division 2 hazardous locations.
- Recommended cable gland: Belden BTC075A0551RA.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 10 AWG |
| Conductor stranding | 7x18 |
| Conductor Material | BC - Bare Copper |
| Segmented ground wire | 3 |
| Ground size | 14 AWG |
| Ground stranding | 7x22 |
| Ground material | BC - Bare Copper |
| Insulation Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Nom. thickness | 0.030 in (0.76 mm) |
| Nom. insulation diameter | 0.172 in (4.37 mm) |
| Color Code | ICEA Chart M4 |
| Shield Coverage | 100% |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Nom. jacket thickness | 0.060 in (1.5 mm) |
| Overall cable diameter (nominal) | 0.506 in (12.9 mm) |
| Armor | No |
| Composite | No |
| Nom. conductor DCR | 0.895 Ohm/1000ft (2.94 Ohm/km) |
| Nom. capacitance cond-to-cond | 31 pF/ft (100 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 60 pF/ft (200 pF/m) |
| Nom. characteristic impedence | 44 Ohm |
| Nom. velocity of prop. | 55% |
| Max. current | 40 Amps per Conductor at 30ºC |
| Nom. outer shield DCR | 0.82 Ohm/1000ft (2.7 Ohm/km) |
| Operating | -40°C To +90°C |
| Stationary min. bend radius | 6.1 in (150 mm) |
| Installation min. bend radius | 6.1 in (150 mm) |
| Max Pull Tension | 400 lbs (180 kg) |
| Bulk cable weight | 238 lbs/1000ft (354 kg/km) |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, TC-ER, XHHW-2 |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Other Part Numbers | 29523C 010, 29523C 010100, 29523C 010250, 29523C 010500, 29523C 0101000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.