Belden 29527C Basics VFD is a shielded VFD cable for Variable Frequency Drives (VFD) and AC motor and drive systems, including Class 1 Division 2 hazardous locations. It is built with 3 x 2 AWG BC - Bare Copper conductors, XLPE - Cross-Linked Polyethylene (Thermoset) insulation, and a black PVC - Polyvinyl Chloride jacket. This cable includes a symmetrical segmented ground (3 x 10 AWG totaling 5AWG) and dual Bare Copper tape shields with 100% coverage to help reduce electrical noise. It is rated 600V with a UL Voltage Rating of 1000 V (TC-ER) and a UL temperature rating of 90°C Dry, 90°C Wet.
Belden 29527C Key Features
- Designed for Variable Frequency Drives (VFD), AC motor and drive systems, and Class 1 Division 2 hazardous locations.
- 3 x 2 AWG BC - Bare Copper circuit conductors with 7x10 stranding and ASTM B3 Copper B8 Class B Stranding notes.
- Includes ground wires with a segmented ground wire: 3 x 10 AWG, ground stranding: 7x18, and ground notes: Segmented Ground (3 Totaling 5AWG).
- Shielded construction with Overall Dual Copper Tapes Helically Applied Shield, Bare Copper (BC) material, and 100% coverage.
- Black PVC - Polyvinyl Chloride jacket with Sunlight Resistance and Oil Resistant properties.
- Rated 600V with UL Voltage Rating: 1000 V (TC-ER) and UL temperature: 90°C Dry, 90°C Wet.
Belden 29527C Applications
- Supports power connections in Variable Frequency Drives (VFD) where reliable operation is required.
- Fits AC motor and drive systems where electrical noise reduction is important for system performance.
- Use it in Class 1 Division 2 hazardous locations when the application calls for this cable type.
- Install it in Indoor and Outdoor environments, including Sunlight Resistance and Burial conditions, when those settings are required.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 2 AWG |
| Conductor stranding | 7x10 |
| Conductor Material | BC - Bare Copper |
| Conductor notes | ASTM B3 Copper B8 Class B Stranding |
| Ground wires | Yes |
| Number of ground wires | 3 |
| Segmented ground wire | 3 x 10 AWG |
| Ground stranding | 7x18 |
| Ground material | BC - Bare Copper |
| Ground notes | Segmented Ground (3 Totaling 5AWG) |
| Insulation Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Nom. thickness | 0.047 in (1.2 mm) |
| Nom. insulation diameter | 0.377 in (9.58 mm) |
| Color Code | ICEA Chart M4 |
| Outer shield type | Helical tape |
| Shield Material | Bare Copper (BC) |
| Coverage | 100% |
| Overall Shield Construction | Overall Dual Copper Tapes Helically Applied Shield |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Nom. jacket thickness | 0.083 in (2.1 mm) |
| Nom. diameter | 0.990 in (25.1 mm) |
| Overall cable diameter (nominal) | 0.990 in (25.1 mm) |
| Ripcord | Yes |
| Armor | No |
| Composite | No |
| Nom. conductor DCR | 0.14 Ohm/1000ft (0.46 Ohm/km) |
| Nom. capacitance cond-to-cond | 35 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 68 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 44 Ohm |
| Nom. velocity of prop. | 55% |
| Max. current | 130 Amps per Conductor at 30ºC |
| Nom. outer shield DCR | 2.04 Ohm/1000ft (6.69 Ohm/km) |
| Operating | -40°C To +90°C |
| Stationary min. bend radius | 11.9 in (302 mm) |
| Installation min. bend radius | 11.9 in (302 mm) |
| Max Pull Tension | 2851 lbs (1293 kg) |
| Bulk cable weight | 969 lbs/1000ft (1440 kg/km) |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| Markings | SUN RES; DIR BUR; Oil Resistant |
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4, FT4 |
| NEC / UL compliance | Article 336, TC-ER, XHHW-2 |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Other Part Numbers | 29527C 010, 29527C 010100, 29527C 010250, 29527C 010500, 29527C 0101000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.