Belden 29529 010, Flexible Motor Supply Cable 3C 1 0 AWG 1000V PVC

SKU:Belden 29529 010
● In stock
Description
Belden 29529 010 is a 100% ground flexible VFD cable for Variable Frequency Drives (VFD), AC motor and drive systems, and Class 1 Division 2 hazardous locations. It is built with 3 finely stranded 1/0 AWG tinned copper conductors, XLPE - Cross-Linked Polyethylene (Thermoset) insulation, and ICEA Chart M4 color code. For noise control and durability, it includes an overall dual copper tape helically applied shield with 100% coverage and a black PVC - Polyvinyl Chloride outer jacket with ripcord. Rated 600/1000V and 90°C Dry/Wet, it is suitable for indoor, outdoor, sunlight resistance, and burial.
Belden 29529 010 Key Features
- 3 finely stranded 1/0 AWG TC - Tinned Copper conductors with conductor stranding: 7x19x21.
- 1/0AWG symmetrical segmented ground (3 of 4AWG) using BC - Bare Copper with segmented ground wire stranding: 7x19x25.
- XLPE - Cross-Linked Polyethylene (Thermoset) insulation with ICEA Chart M4 color code.
- Overall dual copper tape helically applied shield with 100% coverage; shield material: Bare Copper (BC).
- Black PVC - Polyvinyl Chloride jacket with ripcord.
- Environmental suitability: indoor, outdoor, sunlight resistance, burial; sun resistance: TC SUN RES DIR BUR; oil resistance: Oil Resistant.
- UL temperature: 90°C Dry, 90°C Wet; operating: -40°C To +90°C.
- UL voltage rating: 1000 V (TC, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC).
- Flammability / reaction to fire: UL 1685 UL Loading, FT4, IEEE 1202 FT4.
Belden 29529 010 Applications
- Used for Variable Frequency Drives (VFD) in power and control setups where a VFD cable is specified.
- Suitable for AC motor and drive systems where flexible motor supply cabling is required.
- Specified for Class 1 Division 2 hazardous locations where the installation calls for this cable type.
- Recommended cable gland: Belden BTC150A1501RA.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Product type | VFD |
| Number of Conductors | 3 |
| Conductor size | 1/0 AWG |
| Conductor Material | TC - Tinned Copper |
| Conductor notes | Finely Stranded Tinned Copper optomized for VFD use |
| Ground wires | Yes |
| Number of ground wires | 3 Wire |
| Ground construction | 1/0AWG symmetrical segmented ground (3 of 4AWG) |
| Segmented ground wire size | 4 AWG |
| Segmented ground wire material | BC - Bare Copper |
| Segmented ground notes | Segmented grounds (3 totaling 1/0) |
| Ground wire | No Insulation |
| Nom. thickness | 0.057 in (1.4 mm) |
| Nom. insulation diameter | 0.501 in (12.7 mm) |
| Shield | Shielded |
| Shield Type | Copper tape |
| Outer shield type | Helical tape |
| Coverage | 100% |
| Shield notes | 2 mil helical copper tape for crack resistance and high frequency noise conduction |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Nom. jacket thickness | 0.083 in (2.1 mm) |
| Nom. diameter | 1.258 in (31.95 mm) |
| Overall cable diameter (nominal) | 1.258 in (31.95 mm) |
| Ripcord | Yes |
| Armor | No |
| Composite | No |
| Voltage range | 1KV |
| Nom. Conductor DCR (Conductor(s)) | 0.094 Ohm/1000ft (0.31 Ohm/km) |
| Nom. conductor DCR (segmented ground wire) | 0.09 Ohm/1000ft (0.30 Ohm/km) |
| Nom. outer shield DCR | 0.40 Ohm/1000ft (1.3 Ohm/km) |
| Nom. capacitance cond-to-cond | 37 pF/ft (120 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 50 Ohm |
| Nom. inductance cond-grnd | 0.072 µH/ft |
| Nom. velocity of prop. | 55% |
| Max. current | 170 Amps per Conductor at 30ºC |
| Stationary min. bend radius | 15.1 in (384 mm) |
| Installation min. bend radius | 15.1 in (384 mm) |
| Max Pull Tension | 5530 lbs (2510 kg) |
| Bulk cable weight | 1708 lbs/1000ft (2542 kg/km) |
| NEC / UL compliance | Article 336, TC-ER, WTTC, XHHW-2, UL Flexible Motor Supply Cable |
| CEC / C(UL) compliance | TC |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Ratings & Markings | 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC 1000V CSA AWM I/II A/B 600V RW90 TC SUN RES DIR BUR Oil Resistant |
| Other Part Numbers | 29529 010, 29529 010100, 29529 010250, 29529 010500, 29529 0101000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.