Belden 29529C 010, VFD 3C1 0 600V Black

Belden 29529C

SKU:Belden 29529C 010

$1,375.00

In stock

Description

Specifications

Belden 29529C 010, VFD 3C1 0 600V Black specifications
AttributeValue
Conductor count3
Conductor size1/0 AWG
Conductor stranding19x13
Conductor MaterialBC - Bare Copper
Stranding standardASTM B3 Copper B8 Class B Stranding
Ground5AWG symmetrical segmented ground (3 of 10AWG)
Number of ground wires3 Wire
Segmented ground (3X bare)3 x 10 AWG, 7x18, BC - Bare Copper
Insulation MaterialXLPO - Crosslink Polyolefin
Nom. insulation thickness0.059 in (1.5 mm)
Nom. insulation diameter0.479 in (12.2 mm)
Color CodeICEA Chart M4
Shield TypeHelical tape
Shield MaterialBare Copper (BC)
Shield Coverage100%
Jacket MaterialPVC - Polyvinyl Chloride
Jacket ColorBlack
Nom. jacket thickness0.083 in (2.1 mm)
Nom. diameter1.210 in (30.73 mm)
Overall cable diameter (nominal)1.210 in (30.73 mm)
RipcordYes
Voltage600/1000V
UL Voltage Rating1000 V (TC-ER)
Nom. Conductor DCR (Conductor(s))0.105 Ohm/1000ft (0.344 Ohm/km)
Nom. conductor DCR0.30 Ohm/1000ft (0.98 Ohm/km)
Nom. outer shield DCR1.36 Ohm/1000ft (4.46 Ohm/km)
Nom. capacitance cond-to-cond30 pF/ft (98 pF/m)
Nom. capacitance cond-to-other (conds + Shield)55 pF/ft (180 pF/m)
Nom. characteristic impedence36 Ohm
Nom. inductance0.143 µH/ft (0.469 µH/m)
Nom. velocity of prop.55%
Max. current170 Amps per Conductor at 30ºC (per NEC)
Operating-40°C To +90°C
Bend radius (stationary min.)14.5 in (368 mm)
Bend radius (installation min.)14.5 in (368 mm)
Max Pull Tension4264 lbs (1934 kg)
Bulk cable weight1423 lbs/1000ft (2118 kg/km)
Environmental suitabilityIndoor, Outdoor, Sunlight Resistance, Burial
MarkingSUN RES DIR BUR
ResistanceOil Resistant
NEC / UL complianceArticle 336, TC-ER, XHHW-2
Flammability / reaction to fireUL 1685 UL Loading, IEEE 1202 FT4, FT4
ICEA complianceS-95-658
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC complianceChina RoHS II (GB/T 26572-2011)
Other standard compliance(s)P-07-KA070003-MSHA
SustainabilityCA Prop 65
Other Part Numbers29529C 010, 29529C 010100, 29529C 010250, 29529C 010500, 29529C 0101000, UPC 612825138006
Priced PerFT

Documents

Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.

Need a cut length, bulk pricing, or a spec sheet?