Belden 29532C 010, VFD 3C4 0 600V Black

SKU:Belden 29532C 010
● In stock
Description
Belden 29532C 010 is a Belden Basics VFD cable for Variable Frequency Drives (VFD) and AC motor and drive systems, including Class 1 Division 2 hazardous locations. It features 3 x 4/0 AWG (19x10) BC - Bare Copper conductors with XLPE - Cross-Linked Polyethylene (Thermoset) insulation and ICEA Chart M4 color code. The construction includes a 3AWG symmetrical segmented ground (3 x 8 AWG) in continuous contact with the shield, plus an overall dual copper tape helically applied shield with 100% coverage. A black PVC - Polyvinyl Chloride jacket with ripcord supports Indoor, Outdoor, Sunlight Resistance, and Burial, with 600V and 1000 V (TC-ER) ratings and 90°C Dry, 90°C Wet temperature rating.
Belden 29532C 010 Key Features
- Designed as a Belden Basics VFD cable for Variable Frequency Drives (VFD), AC motor and drive systems, and Class 1 Division 2 hazardous locations.
- 3 x 4/0 AWG (19x10) BC - Bare Copper conductors with XLPE - Cross-Linked Polyethylene (Thermoset) insulation and ICEA Chart M4 color code.
- 3AWG symmetrical segmented ground (3 x 8 AWG) in continuous contact with the shield.
- Overall dual copper tape helically applied shield with 100% coverage for noise control and drive performance.
- Black PVC - Polyvinyl Chloride jacket with ripcord; environmental suitability: Indoor, Outdoor, Sunlight Resistance, Burial.
- Voltage range: 600V; UL voltage rating: 1000 V (TC-ER); voltage rating: 1000 V (CSA AWM I/II A/B).
- UL temperature: 90°C Dry, 90°C Wet; operating: -40°C To +90°C.
Belden 29532C 010 Applications
- Use it in Variable Frequency Drives (VFD) installations where a dedicated VFD cable is specified for drive-to-motor connections.
- Install it in AC motor and drive systems in industrial electrical setups where consistent drive performance and noise control are important.
- Specify it for Class 1 Division 2 hazardous locations when the installation requires a cable engineered for that environment.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 4/0 AWG |
| Conductor stranding | 19x10 |
| Conductor Material | BC - Bare Copper |
| Conductor notes | ASTM B3 Copper B8 Class B Stranding |
| Ground wire | 3 x 8 AWG |
| Ground wire stranding | 7x16 |
| Ground wire material | BC - Bare Copper |
| Ground notes | Segmented Ground (3AWG Total of 3) |
| Insulation material (conductor) | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Ground wire insulation | No Insulation |
| Shield Type | Helical Tape |
| Shield Material | Bare Copper (BC) |
| Coverage | 100% |
| Overall Shield Construction | Overall Dual Copper Tape Helically Applied Shield |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Ripcord | Yes |
| Nom. thickness | 0.059 in (1.5 mm) |
| Nom. insulation diameter | 0.630 in (16.0 mm) |
| Nom. jacket thickness | 0.083 in (2.1 mm) |
| Nom. diameter | 1.536 in (39.01 mm) |
| Overall cable diameter (nominal) | 1.536 in (39.01 mm) |
| Nom. conductor DCR | 0.052 Ohm/1000ft (0.17 Ohm/km) |
| Nom. capacitance cond-to-cond | 33 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 60 pF/ft (200 pF/m) |
| Nom. characteristic impedence | 56 Ohm |
| Nom. inductance | 0.136 µH/ft (0.446 µH/m) |
| Nom. velocity of prop. | 55% |
| Max. current | 260 Amps per Conductor at 30ºC (per NEC) |
| Nom. outer shield DCR | 1.16 Ohm/1000ft (3.81 Ohm/km) |
| Stationary min. bend radius | 18.4 in (467 mm) |
| Installation min. bend radius | 18.4 in (467 mm) |
| Max Pull Tension | 8250 lbs (3740 kg) |
| Bulk cable weight | 2576 lbs/1000ft (3834 kg/km) |
| Oil Resistant | Oil Resistant |
| SUN RES | SUN RES |
| DIR BUR | DIR BUR |
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4, FT4 |
| NEC / UL compliance | Article 336, TC-ER, XHHW-2 |
| AWM compliance | AWM I/II A/B |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Other Part Numbers | 29532C 010, 29532C 010100, 29532C 010250, 29532C 010500, 29532C 0101000, UPC 612825138273 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.