Belden 3076F 006, Multi Conductor DataBus ISA SP 50 TW PR 18 AWG PVC

SKU:Belden 3076F 006
● In stock
Description
Belden 3076F 006 is a flexible, foil-shielded fieldbus cable for harsh-environment digital and serial two-way communication. It is built with 1 pair of 18 AWG (7x26) TC - Tinned Copper conductors with PP - Polypropylene insulation, plus a Bi-Laminate (Alum+Poly) tape shield and a 20 AWG (7x28) TC drainwire. The cable has a PVC - Polyvinyl Chloride outer jacket and is rated for indoor and outdoor use with SUN RES and OIL RES jacket attributes. It supports Profibus process automation or Foundation FieldBus process automation and meets PLTC-ER, ITC-ER, CMX-Outdoor, and CM listings.
Belden 3076F 006 Key Features
- Flexible, foil-shielded fieldbus cable designed for harsh-environment digital and serial two-way communication.
- 1 pair of 18 AWG (7x26) TC - Tinned Copper conductors with PP - Polypropylene insulation.
- Bi-Laminate (Alum+Poly) tape shield with 100% coverage and a 20 AWG (7x28) TC drainwire.
- PVC - Polyvinyl Chloride outer jacket with SUN RES and OIL RES attributes for indoor and outdoor use.
- Supports Profibus process automation or Foundation FieldBus process automation.
- Listings include PLTC-ER, ITC-ER, CMX-Outdoor, and CM.
Belden 3076F 006 Applications
- Use it for harsh-environment digital and serial two-way communication where reliable signaling is required.
- Deploy it for Profibus process automation or Foundation FieldBus process automation in industrial control and process automation networks.
- It is designed for demanding industrial sites such as oil and gas extraction and refining sites and petrochemical facilities.
- For remote locations, it fits long distance applications where fieldbus communication needs to be extended across long runs.
- It is appropriate for installations with exposure to humidity/moisture, dust, and oil.
- It is suitable for extreme temperature environments.
- It is intended for environments with exposure to rodent, crush, or cut through force.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 1 pair |
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PP - Polypropylene |
| Nom. thickness (insulation) | 0.022 in (0.56 mm) |
| Nom. insulation diameter | 0.088 in (2.2 mm) |
| Color Code | Blue & Orange |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Nom. thickness (jacket) | 0.050 in (1.3 mm) |
| Overall cable diameter (nominal) | 0.280 in (7.11 mm) |
| Jacket OD +/- | 0.010 |
| Jacket Color | Blue |
| Bulk cable weight | 44 lbs/1000ft |
| Nom. conductor DCR | 7.2 Ohm/1000ft |
| Nom. outer shield DCR | 8.5 Ohm/1000ft (28 Ohm/km) |
| Nom. capacitance (Cond-to-Shield) | 45 pF/ft (150 pF/m) |
| Max. capacitance unbalance | 1.2 pF/ft |
| Nom. characteristic impedence | 100 Ohm |
| Nom. inductance | 0.19 µH/ft (0.62 µH/m) |
| Nom. velocity of prop. | 66% |
| Max. current | 5.2 Amps per Conductor at 25ºC |
| Nom. insertion loss (attenuation) | 0.08 dB/100ft at 0.039 MHz |
| UL Voltage Rating | 300 V (CM, PLTC-ER), 150 V (ITC-ER) |
| UL temperature | 105°C |
| Operating temperature | -40°C to +105°C |
| Stationary min. bend radius | 6.5 in (170 mm) |
| Installation min. bend radius | 2.80 in (71.1 mm) |
| Max Pull Tension | 60 lbs (27 kg) |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Oil Resistance, Burial |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, IEEE 1202, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC, TC |
| CEC / C(UL) compliance | CMG |
| ISO/IEC compliance | IEC 61158-2 |
| Other standard compliance(s) | ISA/SP-50 Type A |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 3076F 006, 3076F 006100, 3076F 006250, 3076F 006500, 3076F 0061000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.