Belden 3077F 003, Multi Conductor DataBus ISA SP 50 22 AWG PVC

SKU:Belden 3077F 003
● In stock
Description
Belden 3077F 003 is a flexible Fieldbus Cable for harsh environment digital and serial two-way communication. It features 1 pair of 22 AWG (7x30) TC - Tinned Copper conductors with PP - Polypropylene insulation and an overall Beldfoil® shield. The PVC - Polyvinyl Chloride outer jacket is rated for Outdoor and Sunlight Resistance. Electrical performance includes 100 Ohm nominal characteristic impedence and 44 pF/ft (140 pF/m) nominal capacitance Cond-to-Shield.
Belden 3077F 003 Key Features
- Flexible Fieldbus Cable design for harsh environment digital and serial two-way communication.
- 1 pair of 22 AWG (7x30) TC - Tinned Copper conductors with PP - Polypropylene insulation.
- Overall Beldfoil® shield with Tape construction, Bi-Laminate (Alum+Poly) material, and 100% coverage.
- PVC - Polyvinyl Chloride outer jacket with Outdoor and Sunlight Resistance.
- Electrical characteristics include 100 Ohm nominal characteristic impedence and 44 pF/ft (140 pF/m) nominal capacitance Cond-to-Shield.
Belden 3077F 003 Applications
- Supports harsh environment digital and serial two-way communication where dependable signaling is required.
- Commonly used in oil and gas extraction and refining sites.
- Fits petrochemical facilities.
- Used for Profibus process automation or Foundation FieldBus process automation installations.
- Performs in extreme temperature environments.
- Handles installations with exposure to humidity/moisture, dust, and oil.
- Works well for remote locations and long distance applications.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Insulation thickness (nominal) | 0.015 in (0.38 mm) |
| Insulation color code | Blue & Orange |
| Drain Wire | 22 AWG (7x30) TC |
| Jacket thickness (nominal) | 0.037 in (0.94 mm) |
| Overall cable diameter (nominal) | 0.197 in (5.00 mm) |
| Jacket Color | Orange |
| Bulk cable weight | 18 lbs/1000ft (27 kg/km) |
| Nom. conductor DCR | 17.1 Ohm/1000ft (56.1 Ohm/km) |
| Nom. outer shield DCR | 11.4 Ohm/1000ft (37.4 Ohm/km) |
| Max. capacitance unbalance | 1.2 pF/ft |
| Nom. inductance | 0.2 µH/ft (0.66 µH/m) |
| Nom. velocity of prop. | 66% |
| Max. current | 2.5 Amps per Conductor |
| Nom. insertion loss (attenuation) [dB/100ft] | 0.14 at 0.039 MHz |
| UL Voltage Rating | 300 V (CM, PLTC), 150 V (ITC) |
| UL temperature | 105°C |
| Operating temperature | -30°C to +105°C |
| Max Pull Tension | 27 lbs (12 kg) |
| Flammability / reaction to fire | UL1685 UL Loading, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 725, Article 727, Article 800, CM, ITC, PLTC |
| CEC / C(UL) compliance | CM |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Multi-Pair Cable |