Belden 3082A T5U, 2C 15 AWG 2C 18 AWG Shield PVC

SKU:Belden 3082A T5U
● In stock
Description
Belden 3082A T5U DeviceBus® Cable is designed for ODVA DeviceNet™ device-level communication in harsh industrial environments and supports CIP (common Industrial Protocol) networks in bus topology for control, configuration, and data collection. It features 2 pairs with stranded TC - Tinned Copper conductors, including a 15 AWG power pair and an 18 AWG data pair. For noise immunity, each pair includes a 100% Bi-Laminate (Alum+Poly) tape shield, plus an overall Tinned Copper (TC) braid with 65% coverage and an 18 AWG (19x30) TC drainwire. A PVC - Polyvinyl Chloride jacket with CMG and PLTC-ER ratings supports indoor/outdoor installations with Sunlight Resistance and Oil Resistance.
Belden 3082A T5U Key Features
- Supports ODVA DeviceNet™ device-level communication and CIP (common Industrial Protocol) networks in bus topology for control, configuration, and data collection.
- 2 pairs with stranded TC - Tinned Copper conductors, including a 15 AWG power pair and an 18 AWG data pair.
- Braid over foil shield design with individual 100% Bi-Laminate (Alum+Poly) tape shields on each pair, plus an overall Tinned Copper (TC) braid with 65% coverage.
- Includes an 18 AWG (19x30) TC drainwire.
- PVC - Polyvinyl Chloride jacket with environmental suitability listed as Indoor, Outdoor, Sunlight Resistance, Oil Resistance.
- UL voltage rating: 300 V (CMG, PLTC-ER), 600 V (AWM 20201).
- Operating: -20°C to +60°C.
- NEC rating: NEC CMG & PLTC-ER.
Belden 3082A T5U Applications
- Intended for harsh environment, ODVA device-level communication.
- Used with CIP (common Industrial Protocol) for control, configuration, and data collection between devices such as sensors and actuators and higher level devices such as PLC and PC in industrial automation.
- Supports device communications in bus topology.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor count | 2 PAIRS |
| Power pair(s) | 1 pair, 15 AWG, 19x27, TC - Tinned Copper |
| Data pair(s) | 1 pair, 18 AWG, 19x30, TC - Tinned Copper |
| Conductor Type | Stranded Conductor |
| Power pair insulation | PVC - Polyvinyl Chloride, 0.021 in (0.53 mm) nominal thickness, 0.109 in (2.77 mm) nominal Insulation Diameter, Red & Black |
| Data pair insulation | PE - Polyethylene (Foam), 0.053 in (1.3 mm) nominal thickness, 0.150 in (3.81 mm) nominal Insulation Diameter, Blue & White, HDPE |
| Shield construction | Individual & Overall Braid Shield |
| Inner shield (power pair(s)) | Tape, Bi-Laminate (Alum+Poly), 100% coverage |
| Inner shield (data pair(s)) | Tape, Bi-Laminate (Alum+Poly), 100% coverage |
| Outer shield | Braid, Tinned Copper (TC), 65% coverage |
| Jacket Material | PVC - Polyvinyl Chloride |
| Outer jacket | PVC - Polyvinyl Chloride, 0.060 in (1.5 mm) nominal thickness |
| Overall cable diameter (nominal) | 0.480 in (12.2 mm) |
| Outer jacket nominal diameter | 0.480 in (12.2 mm) |
| Jacket OD +/- | +/- 0.010 |
| Bulk cable weight | 128 lbs/1000ft |
| Power pair(s) nominal Conductor DCR | 3.58 Ohm/1000ft |
| Power pair(s) nominal inner Shield DCR | 5.75 Ohm/1000ft (18.9 Ohm/km) |
| Power pair(s) nominal inductance | 0.174 µH/ft (0.571 µH/m) |
| Power pair(s) max. current | 16 Amps per Conductor at 30ºC |
| Data pair(s) nominal Conductor DCR | 7.2 Ohm/1000ft (24 Ohm/km) |
| Data pair(s) nominal inner Shield DCR | 3.58 Ohm/1000ft (11.7 Ohm/km) |
| Data pair(s) nominal capacitance Cond-to-Cond | 12 pF/ft (39 pF/m) |
| Data pair(s) nominal characteristic impedence | 120 Ohm |
| Data pair(s) nominal delay | 1.36 ns/ft |
| Data pair(s) nominal velocity of prop. | 75% |
| Data pair(s) max. current | 14 Amps per Conductor at 30ºC |
| Nom. outer shield DCR | 7.29 Ohm/1000ft (23.9 Ohm/km) |
| Voltage Rating | 300 V (AWM I/II A) |
| UL temperature | 60°C |
| Bend radius (stationary min.) | 5.76 in (146 mm) |
| Bend radius (installation min.) | 5.76 in (146 mm) |
| Max Pull Tension | 192.6 lbs (87.36 kg) |
| NEC / UL compliance | Article 725, Article 800, CMG, PLTC |
| AWM compliance | AWM 20201, AWM I/II A |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1685 FT4 Loading, IEEE 1202 FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | ODVA Class 2 Thick |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 3082A T5U, 3082A T5U100, 3082A T5U250, 3082A T5U500, 3082A T5U1000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.