Belden 3092F 010, ControlBus Coax Cable 20 AWG Quad Shield

Description
Belden 3092F 010 is a high-flex ControlBus coax cable built on an RG-6 design with a 20 AWG Stranded (105x40) BC - Bare Copper conductor. It features PE - Polyethylene (Foam) insulation and a quad shield (F/B+F/B) construction using Duobond® II, aluminum braid, Duofoil®, and a second aluminum braid. The PVC - Polyvinyl Chloride outer jacket is Black and rated CMR, with a UL Voltage Rating of 300 V (CMR, CMG). Electrical performance includes 75 Ohm nominal characteristic impedance and 23 dB return loss (5 - 400 MHz).
Belden 3092F 010 Key Features
- High-flex coaxial construction designed on an RG type: 6 platform.
- 20 AWG Stranded (105x40) BC - Bare Copper conductor.
- Quad shield (F/B+F/B) design with Duobond® II (100%), aluminum braid (60%), Duofoil® (100%), and a second aluminum braid (40%).
- PVC - Polyvinyl Chloride outer jacket in Black with NEC / UL compliance: CMR, CL2R and CEC / C(UL) compliance: CMG.
- Nominal characteristic impedance: 75 Ohm, with return loss (5 - 400 MHz): 23 dB.
Belden 3092F 010 Applications
- Use it in harsh environment installations where a high-flex industrial coax is needed.
- Support factory automation networks, including ControlNet™ and Modbus II.
- Install it in Indoor - Riser and Indoor environments, and in Aerial - When supported by messenger Wire.
- Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Conductor nominal diameter | 0.040 in |
| Insulation Material | PE - Polyethylene (Foam) |
| Nominal insulation diameter | 0.183 in (4.65 mm) |
| Insulation color code | White |
| Outer jacket nominal diameter | 0.303 in (7.70 mm) |
| Overall cable diameter (nominal) | 0.303 in (7.70 mm) |
| Flooded | No not flooded over braid |
| Outdoor | No not outdoor grade material |
| Bulk cable weight | 29 lbs/1000ft |
| Nominal conductor DCR | 10.5 Ohm/1000ft |
| Nominal outer shield DCR | 2.6 Ohm/1000ft (8.5 Ohm/km) |
| Nominal Capacitance (Cond-to-Shield) | 16.3 pF/ft (53.5 pF/m) |
| Nominal velocity of prop. | 82% |
| Electrical characteristics notes | IEEE 802.4 MAP/IEEE 802.7 Mini-Map |
| Attenuation (nominal) 1 MHz | 0.36 dB/100ft |
| Attenuation (nominal) 2 MHz | 0.47 dB/100ft |
| Attenuation (Nominal) 5 MHz | 0.8 dB/100ft |
| Attenuation (nominal) 10 MHz | 1.2 dB/100ft |
| Attenuation (nominal) 20 MHz | 2.0 dB/100ft |
| Attenuation (nominal) 50 MHz | 3.2 dB/100ft |
| Attenuation (nominal) 100 MHz | 4.6 dB/100ft |
| Attenuation (nominal) 200 MHz | 6.5 dB/100ft |
| Attenuation (nominal) 300 MHz | 8 dB/100ft |
| Attenuation (nominal) 400 MHz | 9.3 dB/100ft |
| UL temperature | 75°C |
| Operating temperature | -40°C to +75°C |
| Installation min. bend radius | 3 in (76 mm) |
| Max Pull Tension | 35 lbs (16 kg) |
| Environmental suitability | Indoor - Riser, Indoor, Aerial - When supported by messenger Wire |
| Fire rating | Riser |
| Flammability / reaction to fire | UL 1666 Riser |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Item Type | Belden Coaxial Cable RG6 |
| Other Part Numbers | 3092F 010, 3092F 010100, 3092F 010250, 3092F 010500, 3092F 0101000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.