Specifications

Belden 4794R 010, Precision Video Cable 75 Ohm 16 AWG PVC Jacket specifications
AttributeValue
Series type7
Coax TypeRG 7
Plenum number4794P
Overall cable diameter (nominal)0.320 in (8.13 mm)
Conductor nominal diameter0.051 in
Insulation MaterialPE - Polyethylene (Foam)
Insulation nominal diameter0.225 in (5.72 mm)
Insulation color codeWhite
Insulation notesGas Injected
Jacket nominal diameter0.320 in (8.13 mm)
Bulk cable weight55 lbs/1000ft
Nom. velocity of prop.85%
Nom. capacitance (Cond-to-Shield)16.0 pF/ft (52.5 pF/m)
Nom. conductor DCR4.0 Ohm/1000ft
Nom. outer shield DCR1.8 Ohm/1000ft (5.9 Ohm/km)
Return loss (5 - 1600 MHz)23 dB
Return loss (1600 - 4500 MHz)21 dB
Return loss (4500 - 12000 MHz)15 dB
Attenuation (nominal) 1 MHz0.26 dB/100ft
Attenuation (Nominal) 3.58 MHz0.43 dB/100ft
Attenuation (Nominal) 5 MHz0.50 dB/100ft
Attenuation (Nominal) 6 MHz0.52 dB/100ft
Attenuation (Nominal) 7 MHz0.55 dB/100ft
Attenuation (nominal) 10 MHz0.63 dB/100ft
Attenuation (Nominal) 12 MHz0.66 dB/100ft
Attenuation (Nominal) 25 MHz0.88 dB/100ft
Attenuation (Nominal) 55 MHz1.21 dB/100ft
Attenuation (Nominal) 67.5 MHz1.31 dB/100ft
Attenuation (Nominal) 71.5 MHz1.34 dB/100ft
Attenuation (Nominal) 88.5 MHz1.47 dB/100ft
Attenuation (nominal) 100 MHz1.54 dB/100ft
Attenuation (Nominal) 135 MHz1.75 dB/100ft
Attenuation (Nominal) 143 MHz1.79 dB/100ft
Attenuation (Nominal) 180 MHz1.98 dB/100ft
Attenuation (Nominal) 270 MHz2.40 dB/100ft
Attenuation (Nominal) 360 MHz2.76 dB/100ft
Attenuation (Nominal) 540 MHz3.41 dB/100ft
Attenuation (Nominal) 720 MHz3.96 dB/100ft
Attenuation (Nominal) 750 MHz4.05 dB/100ft
Attenuation (nominal) 1000 MHz4.70 dB/100ft
Attenuation (Nominal) 1500 MHz5.83 dB/100ft
Attenuation (Nominal) 2000 MHz6.80 dB/100ft
Attenuation (Nominal) 2250 MHz7.25 dB/100ft
Attenuation (Nominal) @ 3000 MHz8.48 dB/100ft
Attenuation (Nominal) 4500 MHz10.66 dB/100ft
Attenuation (Nominal) 6000 MHz12.47 dB/100ft
Attenuation (Nominal) 12000 MHz19.45 dB/100ft
UL temperature60°C
Operating temperature-20°C to +75°C
Installation min. bend radius3.2 in (81 mm)
Max Pull Tension84 lbs (38 kg)
Flammability / reaction to fireUL1666 Vertical Shaft
Environmental suitabilityIndoor - Riser, Indoor, Aerial - Black only, When supported by messenger Wire
CPR complianceCPR Euroclass: Eca; CPR UKCA Class: Eca
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
SustainabilityCA Prop 65
Priced PerFT

Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.

Need a cut length, bulk pricing, or a spec sheet?

Our team quotes custom lengths and volume orders, usually same day.