Belden 602PTZ 000, Composite PTZ Camera Cable RG59 2C18 SH

SKU:Belden 602PTZ 000
● In stock
Description
Belden 602PTZ 000 is a composite PTZ (CCTV + Control + Power) Cable designed for indoor plenum installations with CMP compliance and NFPA 262 flammability performance. It combines 1-RG59 (RG 59/U) 20 AWG solid BC - Bare Copper video coax with foam FEP insulation and a 95% Bare Copper braid for 75 Ohm video transmission. For control and power, it includes 1-18 AWG stranded BC - Bare Copper pair with FEP insulation and a Beldfoil® shield, plus 2-18 AWG stranded BC - Bare Copper conductors with PVC - Polyvinyl Chloride, Flamarrest® insulation. The Siamese construction with Flamarrest® jacketing helps streamline PTZ camera runs.
Belden 602PTZ 000 Key Features
- Composite PTZ (CCTV + Control + Power) Cable design that combines video coax, a control pair, and power conductors in one run.
- Plenum-CMP construction with UL flammability NFPA 262 and Plenum (Y/N): Yes.
- Video coax section: 1-RG59 (RG 59/U) with 75 Ohm characteristic impedance for video transmission.
- Shielding includes a coax braid (Bare Copper (BC), 95% coverage) and a control pair tape shield (Bi-Laminate (Alum+Poly), Beldfoil®, 100% coverage).
- Outer jacket: Banana Peel (No Overall Jacket), nominal diameter 0.363 in.
Belden 602PTZ 000 Applications
- Use it in surveillance installations where a single composite cable is preferred to route video, control, and power to a camera location.
- For CCTV camera connections, it helps simplify routing and organization with a combined run.
- In PTZ (Pan-Tilt-Zoom) setups, it supports running camera control and power alongside the video feed.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Cable type | PTZ (CCTV + Control + Power) Cable |
| Environmental space | Indoor - Plenum |
| NEC articles | Article 800 |
| NEC / UL compliance | CMP |
| CPR Euroclass | Eca |
| RG type | 59 |
| Number of Conductors | 5 |
| Coax conductor | 20 AWG solid BC - Bare Copper, nominal diameter 0.032 in (No. of coax: 1) |
| Pair1 conductors | 18 AWG stranded 19x30 BC - Bare Copper, nominal diameter 0.044 in (No. of Conductors: 2) |
| Pair2 conductors | 18 AWG stranded 7x26 BC - Bare Copper, nominal diameter 0.047 in (No. of Conductors: 2) |
| Coax insulation | FEP - Fluorinated Ethylene Propylene (Foam), nominal diameter 0.133 in |
| Pair1 insulation | FEP - Fluorinated Ethylene Propylene, nominal diameter 0.059 in |
| Pair2 insulation | PVC - Polyvinyl Chloride, Flamarrest®, nominal wall thickness 0.009 in |
| Inner jacket | PVC - Polyvinyl Chloride, Flamarrest®, nominal diameter 0.193 in, nominal wall thickness 0.016 in; PVC - Polyvinyl Chloride, Flamarrest®, nominal diameter 0.150 in, nominal wall thickness 0.014 in; PVC - Polyvinyl Chloride, Flamarrest®, nominal diameter 0.158 in, nominal wall thickness 0.015 in |
| Outer jacket | No Jacket, nominal diameter 0.363 in |
| Color code (coax core) | White |
| Color code (Pair1) | Blue & White/Blue |
| Color code (Pair2) | Black & Red |
| UL Voltage Rating | 300 V RMS |
| Delay (coax) | max. delay skew 84 ns/100m; nominal delay 1.21 ns/ft; nominal velocity of propagation (VP) 84% |
| Capacitance (coax) | 16.1 pF/ft Conductor to Shield |
| Capacitance (Pair1) | 51 pF/ft Conductor to Conductor; 97 pF/ft Conductor to Shield |
| Capacitance (Pair2) | 30 pF/ft Conductor to Conductor |
| Max. recommended current (Pair1) | 5.2 Amps per Conductor at 25ºC |
| Max. recommended current (Pair2) | 5 Amps per Conductor at 25ºC |
| Conductor DCR (coax) | nominal Conductor DCR 10 Ohm/1000ft; nominal inner Shield DCR 2.5 Ohm/1000ft |
| Conductor DCR (Pair1) | nominal Conductor DCR 5.5 Ohm/1000ft; nominal inner Shield DCR 7.3 Ohm/1000ft; nominal outer Shield DCR 7.3 Ohm/1000ft |
| Conductor DCR (Pair2) | nominal Conductor DCR 6.5 Ohm/1000ft |
| Insertion loss @ 1 MHz | .29 dB/100ft |
| Insertion loss 5 MHz | 0.7 dB/100ft |
| Insertion loss @ 10 MHz | 1.1 dB/100ft |
| Insertion loss @ 50 MHz | 1.8 dB/100ft |
| Insertion loss @ 100 MHz | 2.7 dB/100ft |
| Insertion loss @ 200 MHz | 3.9 dB/100ft |
| Insertion loss @ 400 MHz | 5.9 dB/100ft |
| Insertion loss @ 700 MHz | 8.5 dB/100ft |
| Insertion loss @ 900 MHz | 10 dB/100ft |
| Insertion loss @ 1000 MHz | 10.7 dB/100ft |
| Installation temperature range | 0°C To +75°C |
| Operating Temperature Range | -10°C To +75°C |
| Separation temp range | 0°C To +75°C |
| UL Temperature Rating | 75°C |
| Bulk cable weight | 65 lbs/1000ft |
| Maximum recommended pulling tension | 162 lbs |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU directive compliance | Yes |
| EU CE mark | Yes |
| MII Order #39 (China RoHS) | Yes |
| Non-Plenum number | 502PTZ |
| Footnote | C - CRATE REEL PUT-UP. |
| Patent info | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 602PTZ 0001000, UPC 612825172062 |
| Priced Per | FT |
Documents