Belden 6545PA 008, Multi Conductor Pro Audio Intercom 6C 22 AWG FEP

SKU:Belden 6545PA 008
● In stock
Description
Belden 6545PA 008 is a plenum-rated security, pro audio & intercom cable with 6 pair 22 AWG stranded (7x30) BC - bare copper conductors and FEP - fluorinated ethylene propylene insulation. Each pair is individually shielded with Beldfoil® tape (alum side facing in) and includes a 24 AWG (7x32) TC drainwire to help reduce noise in signal runs. It is finished with a gray PVDF - polyvinylidene fluoride jacket with ripcord and meets NFPA 262 (UL 910) and CMP requirements. Sequential footage marking every two ft helps streamline measuring and installation.
Belden 6545PA 008 Key Features
- 6 pair 22 AWG stranded (7x30) BC - bare copper conductors for security, audio, and intercom signal wiring.
- FEP - fluorinated ethylene propylene insulation with color code: Black & Red, Black & White, Black & Green, Black & Blue, Black & Yellow, Black & Brown.
- Individually shielded pairs with Beldfoil® tape (alum side facing in) and 100% coverage.
- Gray PVDF - polyvinylidene fluoride jacket with ripcord to support easier pulls and termination.
- Plenum suitability for indoor - plenum installations with NFPA 262 (UL 910) and CMP compliance.
- Sequential footage marking every two ft for streamlined measuring and installation.
Belden 6545PA 008 Applications
- Use in security installations where individually shielded pairs help manage noise in multi-pair signal runs.
- Choose for pro audio wiring where consistent electrical characteristics and pair shielding are important for signal integrity.
- Install in intercom systems that benefit from organized multi-pair construction and clear footage marking during installation.
- Specify for indoor - plenum environments where NFPA 262 (UL 910) and CMP requirements apply.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 6 |
| Element type | Pair(s) |
| Insulation thickness (nom.) | 0.010 in (0.25 mm) |
| Insulation diameter (nom.) | 0.049 in (1.2 mm) |
| Inner shield type | Tape |
| Inner shield material | Bi-Laminate (Alum+Poly) |
| Drain Wire | 24 AWG (7x32) TC |
| Outer shield | No Shield |
| Jacket thickness (nom.) | 0.015 in (0.38 mm) |
| Overall cable diameter (nom.) | 0.3 in |
| Bulk cable weight | 60 lbs/1000ft |
| UL Voltage Rating | 300 V |
| Conductor DCR (nom.) | 17.6 Ohm/1000ft |
| Inner shield DCR (nom.) | 15.3 Ohm/1000ft (50.2 Ohm/km) |
| Max. current | 4.2 Amps per Conductor at 30ºC |
| Capacitance, Cond-to-Cond (nom.) | 27.5 pF/ft (90.2 pF/m) |
| Capacitance, Cond-to-other (nom.) | 49.5 pF/ft (162 pF/m) |
| Characteristic impedence (nom.) | 50 Ohm |
| Delay (nom.) | 1.47 ns/ft |
| Inductance (nom.) | 0.18 µH/ft (0.59 µH/m) |
| Velocity of prop. (nom.) | 69% |
| UL temperature | 150°C |
| Operating temperature | -15°C to +150°C |
| Stationary min. bend radius | 3 in (76 mm) |
| Installation min. bend radius | 3 in |
| Max Pull Tension | 114 lbs (51.7 kg) |
| Flammability / reaction to fire | NFPA 262 (UL 910), FT6 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 6545PA 0081000, UPC 612825430049 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.