Contact1-800-975-3686
Ramcorp Wire & Cable

Belden 7895A T5U, 2C 18 AWG 2C 20 AWG Shielded PVC

Belden 7895A T5U

SKU:Belden 7895A T5U

$814.80

In stock

Description

Specifications

Belden 7895A T5U, 2C 18 AWG 2C 20 AWG Shielded PVC specifications
AttributeValue
Power pair1 pair, 18 AWG, 19x30, TC - Tinned Copper
Data pair1 pair, 20 AWG, 19x32, TC - Tinned Copper
Conductor TypeStranded conductor
Power pair insulationPVC - Polyvinyl Chloride, 0.018 in (0.46 mm) nominal thickness, 0.080 in (2.0 mm) nominal insulation diameter, Red & Black
Data pair insulationPE - Polyethylene (Foam), 0.040 in (1.0 mm) nominal thickness, 0.129 in (3.28 mm) nominal insulation diameter, Blue & White
Inner shield (power pair)Tape, Bi-Laminate (Alum+Poly), 100%
Inner shield (data pair)Tape, Bi-Laminate (Alum+Poly), 100%
Shield constructionOverall & individual shields w/drain
Outer jacket materialPVC - Polyvinyl Chloride
Nom. jacket thickness0.045 in (1.1 mm)
Nom. diameter0.378 in (9.60 mm)
Overall cable diameter (nominal)0.378 in (9.60 mm)
Jacket OD +/-0.010
Bulk cable weight76 lbs/1000ft
Power pair nominal conductor DCR6.9 Ohm/1000ft
Power pair max. conductor DCR6.9 Ohm/1000ft
Max. current (power pair)4 Amps Per Conductor at 24 V (per NEC CL2) (Power Pair)
Data pair nominal conductor DCR10.9 Ohm/1000ft (35.8 Ohm/km)
Data pair max. conductor DCR10.9 Ohm/100m
Data pair nominal capacitance (Cond-to-Cond)12 pF/ft (39 pF/m)
Data pair nominal characteristic impedence120 Ohm
Data pair nominal velocity of prop.75%
Nom. outer shield DCR3.2 Ohm/1000ft (10 Ohm/km)
UL temperature75°C
Operating temperature-20°C to +75°C
Bend radius (stationary min.)3.8 in (97 mm)
Bend radius (installation min.)3.8 in (97 mm)
Max Pull Tension65 lbs (29 kg)
Environmental suitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance
Flammability / reaction to fireUL 1685 FT4 Loading, FT4, IEEE 1202, IEC 60332-1-2
CPR complianceCPR Euroclass: Eca
NEC / UL complianceArticle 725, Article 800, CMG, PLTC
AWM complianceAWM 20201
CEC / C(UL) complianceCMG
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
Other standard compliance(s)ODVA Cable III
Item TypeBelden Multi Conductor Cable
Other Part Numbers7895A T5U100, 7895A T5U250, 7895A T5U500, 7895A T5U1000
Priced PerFT

Documents

Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.

Need a cut length, bulk pricing, or a spec sheet?

Our team quotes custom lengths and volume orders, usually same day.