Belden 7897A T5U, DeviceBus 2C 15 AWG 2C 18 AWG Shielded PVC Gray

SKU:Belden 7897A T5U
● In stock
Description
Belden 7897A T5U DeviceBus® for ODVA DeviceNet™ Cable is designed for device-level communication in industrial automation networks using CIP (common Industrial Protocol). It features 2 pair 15+18AWG (19x27+19x30) TC - Tinned Copper stranded conductors, with PVC/Nylon - Polyvinyl Chloride + Nylon insulation on the power pair(s) and FEP - Fluorinated Ethylene Propylene (Foam) insulation on the data pair(s). The cable includes tape, bi-laminate (Alum+Poly) 100% shielding on each pair, plus an overall tinned copper braid (65%) and an 18 AWG (19x30) TC drainwire. A PVC - Polyvinyl Chloride outer jacket supports Indoor, Outdoor, Sunlight Resistance, and Oil Resistance, with a UL Voltage Rating of 600 V (TC-ER) and NEC / UL compliance to Article 336, TC-ER.
Belden 7897A T5U Key Features
- Supports ODVA device-level communication using CIP (common Industrial Protocol) for industrial automation networks.
- 2 pair 15+18AWG (19x27+19x30) TC - Tinned Copper stranded conductors for combined power and data pair(s).
- Pair-level shielding uses tape and bi-laminate (Alum+Poly) 100% on both power pair(s) and data pair(s), plus an overall tinned copper (TC) braid (65%).
- PVC - Polyvinyl Chloride outer jacket with environmental suitability for Indoor, Outdoor, Sunlight Resistance, and Oil Resistance.
- UL Voltage Rating: 600 V (TC-ER); NEC / UL compliance: Article 336, TC-ER.
Belden 7897A T5U Applications
- Fits harsh-environment installations where device-level communication is required.
- Enables ODVA device-level communication in industrial automation networks.
- Works with CIP (common Industrial Protocol) for control, configuration, and data collection between devices, such as sensors and actuators, and higher level devices such as PLC and PC in industrial automation, bus topology, etc.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Power pair(s) | 1, 15 AWG, 19x27, TC - Tinned Copper |
| Data pair(s) | 1, 18 AWG, 19x30, TC - Tinned Copper |
| Conductor Type | Stranded Conductor |
| Power pair(s) insulation | PVC/Nylon - Polyvinyl Chloride + Nylon, 0.021 in (0.53 mm), 0.109 in (2.77 mm), Red & Black |
| Data pair(s) insulation | FEP - Fluorinated Ethylene Propylene (Foam), 0.050 in (1.3 mm), 0.146 in (3.71 mm), Blue & White |
| Drainwire type | 18 AWG (19x30) TC |
| Nom. jacket thickness | 0.060 in (1.5 mm) |
| Nom. diameter | 0.460 in (11.7 mm) |
| Overall cable diameter (nominal) | 0.460 in (11.7 mm) |
| Jacket OD +/- | 0.015 |
| Bulk cable weight | 125 lbs/1000ft |
| Power pair(s) nom. conductor DCR | 3.6 Ohm/1000ft |
| Power pair(s) max. current | 8 Amps per Conductor at 25ºC |
| Data pair(s) nom. conductor DCR | 6.9 Ohm/1000ft (23 Ohm/km) |
| Data pair(s) nom. capacitance (cond-to-cond) | 12 pF/ft (39 pF/m) |
| Data pair(s) nom. characteristic impedence | 120 Ohm |
| Data pair(s) nom. velocity of prop. | 75% |
| Nom. outer shield DCR | 1.8 Ohm/1000ft (5.9 Ohm/km) |
| UL temperature | 75°C Dry |
| Operating temperature | -20°C to +75°C |
| Bend radius (stationary min.) | 4.4 in (110 mm) |
| Bend radius (installation min.) | 4.4 in (110 mm) |
| Max Pull Tension | 190 lbs (86 kg) |
| Flammability / reaction to fire | UL 1685 UL Loading |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Other standard compliance(s) | ODVA Class 1 Thick |
| Other Part Numbers | 7897A T5U100, 7897A T5U250, 7897A T5U500, 7897A T5U1000 |
| Item Type | Belden Multi-Pair Cable |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.